SAMLEX AMERICA INC. | 41
SECTION 4 | Parameter Setup
Table 4.3 Group 1 Parameter Set Up: CHARGE CURVE (Refer to Menu Map at Fig 4.2, Section 4.1.3.1)
Parameter
Setup
Screen No.
(Column 1)
Parameter
(Column 2)
EVO-1212F
EVO-1212F-HW
(Column 3)
EVO-2212
(Column 4)
EVO-3012
(Column 5)
EVO-1224F
EVO-1224F-HW
(Column 6)
EVO-2224
(Column 7)
EVO-4024
(Column 8)
1
“BULK CURRENT” *See Note 1
(Bulk Charge Current “Io”)
0 – 60A
(Default:20A)
0 – 100A
(Default:40A)
0 – 130A
(Default:40A)
0 – 40A
(Default: 20A)
0 – 70A
(Default:40A)
0 – 110A
(Default:40A)
2
“ABSORP VOLTAGE”
(Absorption Voltage)
12.00 – 16.00V (Default: 14.40V) 24.00 – 32.00V (Default: 28.80V)
3
“EQUALIZE VOLTAGE”
(Equalization Voltage)
14.00 – 16.50V (Default: 14.40V) 28.00 – 33.00V (Default: 28.80V)
4
“FLOAT VOLTAGE”
(Float Voltage)
12.00 – 15.00V (Default: 13.50V) 24.00 – 30.00V (Default: 27.00V)
5
“COMPENSATE”
(Temperature Compensation)
3mV to 5mV/C/Cell
(Default: 4mV/C/Cell)
6
“BATT OVER VOLT”
(Battery Over Voltage Shut Down)
14.00 – 17.00V
(Default: 16.00V)
28.00 – 35.00V
(Default: 32.00V)
7
“RESET VOLTAGE”
(Battery Low Voltage Reset)
12.00 – 17.00V
(Default: 14.00V)
24.00 – 35.00V
(Default: 28.00V)
8
“LOW VOLT ALARM”
(Battery Low Voltage Alarm)
9.50 – 13.50V
(Default: 11.00V)
19.00 – 27.00V
(Default: 22.00V)
9
“BATT LOW VOLTAGE”
(Battery voltage at which inverter shut down/ com-
plete shut down is triggered in conjuction with"LV
DETECT TIME" and "LV CUT OFF TIME")
>9.00 – 13.00V
(Default: 10.50V)
>18.00 – 24.00V
(Default: 21.00V)
10
“LV DETECT TIME”
(Detect time to qualify low battery voltage as
"BATT LOW VOLTAGE" condition)
0 – 600 sec
(Default: 10 sec)
11
“LV CUT OFF TIME”
(Time in "BATT LOW VOLTAGE"condition to
trigger complete shut down)
0 – 7200 sec
(Default: 1200 sec)
12
“EQUALIZE-4STAGES”
(4 Stage Charging On/Off)
0=No (3-stage) ; 1=Yes (4-stage)
(Default: 0=No )
13
"MODE”
0 = Normal (Default).......Grid / Generator priority
Also called Off-Line Mode
1 = On-Line..................Inverter priority
Also called On-Line Mode
2 = Charger Only..........Charging and AC bypass only
No inverting
14
“ONLINE OPTION” 0 = Option 1 (Default); 1 = Option 2
15
“RESET TO BULK”
(Voltage to exit Float Stage to re-charge from
Bulk Stage)
10.00 – 13.00V
(Default: 12.00V)
20.00 – 26.00V
(Default: 24.00V)
16
“GS DETECT TIME” 0 – 600 sec (Default: 10 sec)
17
“GEN ON TIME” 0 – 240 minute (Default: 60 minute)
18
“GEN OFF DELAY” 0 – 240 minute (Default: 60 minute)
19
“ABSORP TIME” 0 – 600 min (Default: 60 min)
20
“ABSORP EXIT AMPS” 0 – 20 A (Default: 4 A)
21
“CHARGING PROFILE”
0 = 3 Stage Adaptive (Default)
1 = 3 Stage Type 1
2 = 3 Stage Type 2
3 = 2 Stage Type 1
4 = 2 Stage Type 2
5 = 2 Stage Type 3
22
“BATTERY TYPE”
0 = Lead Acid (Default)
1 = Lithium
23
“SAFE CHARGING” 0-300 Min (Default: 60 min)
24
"EXT. CHARGER"
0 = Affect (Default)
1 = Not affect
*NOTE
1. "BULK CURRENT" value may automatically reduce in higher ambient temperatures of around 50˚-60˚ if Power Transformer temperature exceeds 130˚C, or Head
Sink temperature exceeds 65˚C. See Section 4.9.3 in EVO-1212F/ 1224F Owner's Manual for more details.