EasyManua.ls Logo

SamplexPower PST-600-12 - Inverter Power Rating Explained

Default Icon
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 | SAMLEX AMERICA INC.
SECTION 2 | General Information
Some new furnaces with microprocessor control / Oil burner primary controls.
High intensity discharge (HID) lamps like Metal Halide Lamps. These may get dam-
aged. Please check with the manufacturer of these types of devices for suitability.
Some uorescent lamps / light xtures that have Power Factor Correction Capacitors.
The inverter may shut down indicating overload.
Induction Cooktops
2.5 POWER RATING OF INVERTERS
i
INFO
For proper understanding of explanations given below, please refer to deni-
tions of Active / Reactive / Apparent / Continuous / Surge Powers, Power Factor,
and Resistive / Reactive Loads at Section 2.1 under “DEFINITIONS”.
The power rating of inverters is specied as follows:
Maximum Continuous Running Power Rating
Surge Power Rating to accommodate high, short duration surge of power required
during start up of certain AC appliances and devices.
Please read details of the above two types of power ratings in Section 2.1 under
“DEFINITIONS”
i
INFO
The manufacturers’ specication for power rating of AC appliances and devices
indicates only the Maximum Continuous Running Power Rating. The high,
short duration surge of power required during start up of some specic types
of devices has to be determined by actual testing or by checking with the
manufacturer. This may not be possible in all cases and hence, can be guessed
at best, based on some general Rules of Thumb.
Table 2.1 provides a list of some common AC appliances / devices that require high,
short duration surge of power during start up. An “Inverter Sizing Factor” has been
recommended against each which is a Multiplication Factor to be applied to the Rated
Continuous Running Power Rating of the AC appliance / device to arrive at the Rated
Continuous Running Power Rating of the inverter.