60 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 61
SECTION 12 | Specications
MODEL NO. PST-600-12 PST-600-24
OUTPUT
OUTPUT VOLTAGE 120 VAC ± 3% 120 VAC ± 3%
MAXIMUM OUTPUT CURRENT 5.1A 5.1A
OUTPUT FREQUENCY 60 Hz ± 1% 60 Hz ± 1%
TYPE OF OUTPUT WAVEFORM Pure Sine Wave Pure Sine Wave
TOTAL HARMONIC DISTORTION
OF OUTPUT WAVEFORM
< 3% < 3%
CONTINUOUS OUTPUT POWER
(At Power Factor = 1)
600 Watts 600 Watts
SURGE OUTPUT POWER 1000 Watts 1000 Watts
PEAK EFFICIENCY > 85% > 85%
AC OUTPUT CONNECTIONS NEMA5-20R GFCI Duplex Outlets. NEMA5-20R GFCI Duplex Outlets.
INPUT
NOMINAL DC INPUT VOLTAGE 12V 24V
DC INPUT VOLTAGE RANGE 10.7 - 16.5 VDC 21.4 - 33 VDC
MAXIMUM DC INPUT CURRENT 80A 40A
DC INPUT CURRENT AT NO LOAD < 600 mA < 450 mA
DC INPUT CONNECTIONS Tubular hole diameter: 7/16"; Set Screw 5/16" x 24TPI 1/2" long, slotted
DC INPUT FUSES (INTERNAL)
2 x 40A = 80A (Each 40A, 32V,
Automotive, Blade Type)
2 x 20A = 40A (Each 20A, 32V,
Automotive, Blade Type)
DISPLAY
LED Power, Overload, Over Temperature Power, Overload, Over Temperature
PROTECTIONS
LOW DC INPUT VOLTAGE ALARM 10.7V ± 0.1V 21.4V ± 0.2V
LOW DC INPUT VOLTAGE SHUTDOWN 10V ± 0.1V ; Auto-reset: 11.5V ± 0.3V 20V ± 0.2V ; Auto-reset: 23V ± 0.5V
HIGH DC INPUT VOLTAGE
SHUTDOWN
16.5V ; Auto-reset: < 16.5V 33V ; Auto-reset: < 33V
SHORT CIRCUIT SHUTDOWN When output voltage drops to 80V or lower
OVERLOAD SHUTDOWN At overload of 110% to 115%
GROUND FAULT SHUTDOWN Through GFCI outlets (6 mA leakage)
OVER TEMPERATURE SHUTDOWN 90°C ± 5°C ; Auto reset at 65°C ± 5°C
REVERSE POLARITY ON
DC INPUT SIDE
External / internal DC sides fuses will blow
REMOTE CONTROL
WIRED REMOTE CONTROL
• Remote Control Model RC-15A with LED display & 5 m/ 16.5 ft cable
connected through Modular Jack Connector (6P6C) (optional)
• 2-Wire & 1-Wire On/ Off control connected through Hardwiring
Terminal Block
COOLING
FORCED AIR COOLING
Temperature controlled fan
Fan ON at 55°C ± 3°C; Fan OFF at 45°C ± 3°C
COMPLIANCE
SAFETY
Intertek - ETL Listed. Conforms to ANSI/UL Standard 458 and certi-
ed to CSA Standard C22.2 No. 107.1-01
EMI / EMC FCC Part 15(B), Class B
HAZARDOUS SUBSTANCE
RESTRICTION
Lead Free
ENVIRONMENT
WORKING ENVIRONMENT Indoor use
OPERATING TEMPERATURE RANGE -20 to 40˚C / -4 to 104˚F
STORAGE TEMPERATURE -30 to 70˚C / -22 to 158˚F
RELATIVE HUMIDITY 90%, non condensing
DIMENSIONS
(W X D X H), MM 238 x 276.2 x 82 238 x 276.2 x 82
(W X D X H), INCHES 9.37 x 10.87 x 3.23 9.37 x 10.87 x 3.23
WEIGHT
KG 2.7 2.7
LBS 5.9 5.9
NOTES:
1. All power ratings are specied for resistive load at Power Factor = 1.
2. All specications given above are at ambient temperature of 25°C / 77°F.
3. Specications are subject to change without notice