EasyManua.ls Logo

Samson 3244 - Replacing the Packing

Samson 3244
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB 8026 EN 9-11
Servicing
9.4.2 Replacing the packing
Risk of control valve damage due to incor-
rect servicing.
Î The packing can only be replaced when
all the following conditions are met:
The valve does not have a balanced
plug.
The valve does not have a bellows
seal.
The standard or ADSEAL packing is
installed in the valve.
Î To replace the packing in other valve ver-
sions, contact our after-sales service.
a) Standard version
Standard packing (PTFE)
1. Undo the body nuts (14) gradually in a
crisscross pattern.
2. Unscrew the stem connector nut (9) and
lock nut (10) from the plug stem (5).
3. Unscrew the threaded bushing (8).
NOTICE
!
16
12
16
15.2
15
15.1
11
2 Flange
5 Plug with plug stem
8 Threaded bushing (packing nut)
11 Spring
12 Washer
15 Packing
15.1 Spacer ring with retaining ring
15.2 Seals
16 Packing rings
16
8
12
11
2
5
Fig.9-3: Standard packing (left) and ADSEAL packing (right)