Questions and Answers

  • J
    Jessica DayJul 28, 2025
    What to do if the Samson Control Unit valve leaks to the atmosphere?
    • N
      Nicholas BriggsJul 28, 2025
      If the Samson Control Unit valve leaks to the atmosphere, it could be due to several reasons. The packing might be defective, requiring replacement. Also, a defective diaphragm could be the cause, which would also need replacing. Another possibility is a loose flanged joint or a worn-out gasket, in which case you should check the flanged joint and replace the gasket if necessary.
  • R
    randall93Aug 5, 2025
    Why doesn't the Samson Control Unit actuator and plug stem move on demand?
    • S
      Susan Hernandez DDSAug 5, 2025
      If the Samson Control Unit actuator and plug stem do not move on demand, it could be due to a blocked actuator. Check the attachment and remove any blockage, remembering to disconnect and lock the pneumatic air supply and control signal first. It could also be caused by a defective diaphragm, which would need to be replaced. Another cause could be signal pressure being too low, so check the signal pressure and the signal pressure line for any leakage.
  • S
    Seth HerringAug 11, 2025
    What to do if there is increased flow through closed Samson 3351 valve?
    • N
      nicholsonthomasAug 11, 2025
      If you notice increased flow through a closed Samson Control Unit valve, it may be due to dirt or foreign particles lodged between the seat and plug. Try shutting off the pipeline section and flushing the valve. Alternatively, the valve trim could be worn out, requiring replacement of the seat and plug. Damaged facing may also be the cause.
  • M
    michelleaguirreAug 20, 2025
    How to fix Samson 3351 actuator and plug stem not stroking through full range?
    • L
      loritaylorAug 20, 2025
      If the Samson Control Unit actuator and plug stem do not stroke through the full range, it could be due to low signal pressure. Ensure you check the signal pressure and the signal pressure line for leaks. Also, verify the settings of the valve accessories, as an incorrect setting can cause this problem.
  • Б
    БекзатAug 14, 2025
    Могу я купить у вас 3351

    Summary

    Definition of signal words

    Safety instructions and measures

    1.1 Notes on possible severe personal injury

    Details risks of severe personal injury from hazards in the equipment.

    1.2 Notes on possible personal injury

    Details risks of personal injury from hazards, noise, or exhaust air.

    1.3 Notes on possible property damage

    Details risks of property damage due to contamination, unsuitable media, or incorrect handling.

    1.4 Warnings on the device

    Explains warning symbols and their meaning on the device.

    Markings on the device

    2.1 Valve nameplate

    Describes the inscriptions and meaning on the valve nameplate.

    Design and principle of operation

    3.1 Versions

    Details the different versions and configurations of the Type 3351 valve.

    3.2 Additional fittings

    Describes optional fittings like strainers, bypass, and test connections.

    3.3 Accessories

    Lists available accessories for mounting valve accessories.

    3.4 Technical data

    Provides technical specifications including pressure, temperature, and materials.

    Malfunctions

    8.1 Troubleshooting

    Table of common malfunctions, causes, and recommended actions.

    8.2 Emergency action

    Procedures for responding to malfunctions and returning to service.

    Servicing

    9.1 Periodic testing

    Recommended inspection and testing intervals to prevent failures.

    9.2 Preparing the valve for service work

    Details necessary preparations and tools for performing service work.

    9.3 Installing the valve after service work

    Steps for reinstalling and putting the valve back into operation.

    9.4 Service work

    General instructions for performing service work on the valve.

    Repairs

    12.1 Returning devices to SAMSON

    Instructions and requirements for returning defective devices for repair.

    Annex

    15.1 Tightening torques, lubricants and tools

    Specifications for tightening torques, lubricants, and special tools.

    15.2 Spare parts

    Instructions on how to contact SAMSON for spare parts.

    15.3 After-sales service

    Contact info and required details for after-sales service.

    15.4 Information on the UK sales region

    Details specific to the UK sales region, including importer information.