3 Alignments and Adjustments
3-1
3-1 Required Equipment
The following equipment is necessary for adjusting the monitor:
Computer with Windows 95, Windows 98, Windows NT, Windows 2000, or Windows XP.
MTI-2031 DDC MANAGER JIG
3-2 Automatic Color Adjustment
To input video, use 16 gray or any pattern using black and white.
1. Press and hold down both the MENU and the
keys at the same time for about 5 seconds.
2. A blinking display informs you that the automatic color adjustment process is completed.
3. The automatic color adjustment feature is also available in the service function.
3-3 DDC EDID Data Input
1. Input DDC EDID data when replacing AD PCB.
2. Receive/Download the proper DDC file for the model from HQ quality control department.
Install the below jig (Figure 1) and enter the data.
3-4 OSD Adjustment When Replacing Panel
1. Set the Brightness and Contrast to zero,
and push the MENU button more than 5 seconds.
The Function OSD is displayed like Figure 2.
2. Select the Panel Information.
3. Select a panel that you want to replace with.
3-5 OSD Adjustment When Replacing Lamp Only
1. Set the Brightness and Contrast to zero,
and push the MENU button more than 5 seconds.
The Function OSD is displayed like Figure 2.
2. Select the Panel Information.
3. Select the upper lamp/ lower lamp.
3 Alignments and Adjustments
This section of the service manual explains how to use the RS232 JIG.
This function is needed for AD board change and program memory (IC200) change.