11
Installation
Control box
Before
connecting
Correct
Upside
down
Damaged Non-circular
After
connecting
Correct
(Front view)
Correct
(Side view)
Upside
down
Non-fitted
<Circular terminal>
CAUTION
• Connect the wires firmly so that wires cannot be pulled
out. Loose wires can cause the connection to overheat.
Each circular terminal must match the size of its
corresponding screw in the terminal block.
CAUTION
• For the terminal block wiring, use a wire with a
ring terminal socket only. Regular wires without a
ring terminal socket may become a hazard as the
connections may loosen during operation.
For the product that uses the R-32 refrigerant, be cautious not
to generate a spark by keeping the following requirements:
‐ Do not remove the fuses with power on.
‐ Do not disconnect the power plug from the wall
outlet with power on.
‐ It is recommended to locate the outlet in a high
position. Place the cords so that they are not tangled.
2 Tighten the terminal block screw.
L1 L2 F1 F2
3 In Step 2-2, step 3 you determined the exit position for the
piping bundle. If using the left, right, or bottom exits, pass
the cables through the selected knockout.
NOTE
• Power supply cords of parts of appliances for outdoor
use shall not be lighter than polychloroprene sheathed
flexible cord. (Code designation IEC: 60245 IEC66/
CENELEC: H07RN-F, IEC: 60245 IEC57 CENELEC:
H05RN-F, IEC: 60227 IEC53: H05VV-F)
• Power & Communication cable shall not exceed 30 m.