Refer to the service manual in the GSPN(see the rear cover) for the more information.
AIR CONDITIONER CONTENTS
SYSTEM AIR CONDITIONER
1. Precautions
2. Product Specifications
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram
6. Wiring Diagram
7. Reference Sheet
AC012/018/024MNADCH
INDOOR UNIT OUTDOOR UNIT
Model :
AC012MNADCH/AA
AC018MNADCH/AA
AC024MNADCH/AA
AC030MNTDCH/AA
AC036MNTDCH/AA
AC012KXADCH/AA
AC018JXADCH/AA
AC024JXADCH/AA
AC030JXADCH/AA
AC036JXADCH/AA
AC012KXADCH
AC024JXADCH
AC030JXADCH
AC018JXADCH
AC036JXADCH
AC030/036MNTDCH

Other manuals for Samsung AC018MNADCH/AA

Questions and Answers:

Samsung AC018MNADCH/AA Specifications

General IconGeneral
RefrigerantR410A
Cooling Capacity18000 BTU/h
Outdoor Unit Dimensions (WxHxD)780 x 540 x 290 mm
Indoor Unit Weight9.5 kg
Outdoor Unit Weight32 kg

Summary

Precautions for Air Conditioner Service

Precautions for the Service

Essential safety guidelines for servicing air conditioners, emphasizing proper part usage and handling.

Precautions related to static electricity and PL

Safety measures to prevent damage from static electricity and protect against potential hazards during service.

Precautions related to product safety

Key safety instructions for handling product power, cables, and user interaction to prevent shock or fire.

Product Specifications and Features

Product Specifications

Detailed technical specifications including dimensions, capacity, power consumption, and noise levels for various models.

Disassembly and Reassembly Procedures

Troubleshooting Guide

Detection of errors

Overview of error codes and corresponding LED display indicators for diagnosing system faults.

Troubleshooting for outdoor unit

A comprehensive list of error codes and troubleshooting steps specifically for outdoor unit malfunctions.

Troubleshooting by symptoms

Diagnostic flowcharts and procedures for addressing common indoor unit operational symptoms and failures.

Indoor FAN error

Troubleshooting steps for diagnosing and resolving indoor fan errors, including connector checks and foreign substance removal.

Communication error after finishing Tracking

Diagnostic guide for communication errors between indoor and outdoor units, involving cable checks and signal measurements.

Indoor unit float sensor error

Steps to troubleshoot indoor unit float sensor failures, including resistance checks and drain pump operation.

EEPROM circuit failure

Procedure for diagnosing and resolving EEPROM circuit failures, involving component checks and PCB replacement.

Outdoor unit is not powered on – Initial diagnosis

Initial diagnostic steps for troubleshooting outdoor units that are not receiving power, checking voltage and connections.

Communication error

Troubleshooting guide for communication errors, focusing on cable connections and PBA replacement.

Outdoor temperature sensor error

Diagnostic steps for outdoor temperature sensor errors, including resistance checks and voltage measurements.

Related product manuals