Step 6 Connecting the refrigerant pipe
Items Maximum allowable length [ft(m)]
Applicable outdoor
unit models
AC018BXADCH
AC024BXADCH
AC030BXADCH
AC036BXADCH
AC042BXADCH
AC048BXADCH
Main pipe (L1) 164.0(50) 246.0(75)
Max. height difference
between outdoor and
indoor units (h1)
98.4(30) 98.4(30)
n=1
h₁
indoor
outdoor
L₁
Temper grade and minimum thickness of the
refrigerant pipe
Outer diameter
[inch(mm)]
Minimum thickness
[inch(mm)]
Temper grade
ø1/4(6.35) 0.0276(0.7)
C1220T-O
ø3/8(9.52) 0.0276(0.7)
ø1/2(12.7) 0.0315(0.8)
ø5/8(15.88) 0.0394(1.0)
ø5/8(15.88) 0.0315(0.8)
C1220T-1/2H OR
C1220T-H
ø3/4(19.05) 0.0354(0.9)
ø7/8(22.23) 0.0354(0.9)
CAUTION
Be sure to use C1220T-1/2H (Semi-hard) pipe for more
than Ø19.05 mm. If you use C1220T-O (Soft) pipe for
Ø19.05 mm, the pipe may be broken, which can result
in an injury.
Make at least one round:
It will reduce noise and vibration
AC018BXADCH
AC024/030/036/042/048XADCH
After
connectiong
the pipes, block
the part .
Make at least one round:
It will reduce noise and vibration
(A) Heat radiation holes
Do not block the holes.
The designs and shape are subject to change
according to the model.
CAUTION
Pipe outlet
Cut the pipe outlet to the exact pipe size. In addition,
remove foreign substances and burres aroud the
outlet.
Perform cutting with only a cutter (ex. nipper)and
never tap with a hammer near the pipe outlet.
Otherwise, it may cause product damage such as
warping of the cabinet.
After connecting the pipes with Pipe outlet, plug the
space around the pipes.
After connecting the pipes, proceed exactly as directed
in the guide to prevent interference with the internal
parts.
Tighten the nuts to the specified torques. If
overtightened, the nuts could be broken so refrigerant
may leak.
Protect or enclose refrigerant tubing to avoid
mechanical damage.
After installing pipes, block the unused knock hole
to prevent small animal from entering. However, the
radiant heat hole(A) should be able to intake air.