Installation
Nominal
dimensions
for cable
[mm2(inch2)]
Nominal
dimensions
for screw
[mm(inch)]
BDd1EFLd2t
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Min.
[mm
(inch)]
Min.
[mm
(inch)]
Max.
[mm
(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Min.
[mm
(inch)]
4/6
(0.006/ 0.009)
4(3/8) 9.5(3/8)
±0.2
(±0.007)
5.6(1/4)
+0.3(+0.011)
-0.2(-0.007)
3.4(1/8)
±0.2
(±0.007)
6 (1/4)
5
(3/16)
20 (3/4) 4.3 (3/16)
+0.2 (+0.007)
0(0)
0.9
(0.03)
8(3/16) 15(9/16) 9 (3/8)
28.5
(1-1/8)
8.4 (1-3/16)
+0.4 (+0.015)
0(0)
10(0.01) 8(3/16) 15(9/16)
±0.2
(±0.007)
7. 1 ( 1/ 4 )
+0.3(+0.011)
-0.2(-0.007)
4.5(3/16)
±0.2
(±0.007)
7. 9
(5/16)
9 (3/8)
30
(1-3/16)
8.4 (1-3/16)
+0.4 (+0.015)
0(0)
1.15
(0.04)
16(0.02) 8(3/16) 16(10/16)
±0.2
(±0.007)
9(3/8)
+0.3(+0.011)
-0.2(-0.007)
5.8(1/4)
±0.2
(±0.007)
9.5
(5/16)
13 (1/2)
33
(1-5/16)
8.4 (1-3/16)
+0.4
(+0.015) 0(0)
1.45
(0.05)
25(0.03)
8(3/16) 12(1/2)
±0.3
(±0.011)
11.5(7/16)
+0.5(+0.019)
-0.2(-0.007)
7. 7 ( 5/ 16 )
±0.2
(±0.007)
11 (3/8)
15
(5/8)
34 (1-
3/8)
8.4 (1-3/16)
+0.4 (+0.015)
0(0)
1.7
(0.06)
8(3/16) 16.5(10/16) 13 (1/2) 8.4 (1-3/16)
35(0.05)
8(3/16) 16(10/16)
±0.3
(±0.011)
13.3(1/2)
+0.5(+0.019)
-0.2(-0.007)
9.4(3/8)
±0.2
(±0.007)
12.5
(1/2)
13 (1/2)
38
(1-1/2)
8.4 (1-3/16)
+0.4 (+0.015)
0(0)
1.8
(0.07)
8(3/16) 22(7/8) 13 (1/2)
43 (1-
11/16)
8.4 (1-3/16)
50(0.07) 8(3/16) 22(7/8)
±0.3
(±0.011)
13.5(1/2)
+0.5(+0.019)
-0.2(-0.007)
11.4(7/16)
±0.3
(±0.011)
17.5
(11/16)
14
(9/16)
50 (2) 8.4 (1-3/16)
+ 0.4(+0.015)
0(0)
1.8
(0.07)
70(0.10) 8(3/16) 24(1)
±0.4
(±0.015)
17.5(11/16)
+0.5(+0.019)
-0.4(-0.015)
13.3(1/2)
20 ±0.4 18.5
+
(3/4)(3/4)(±0.015)
51 (2) 8.4 (1-3/16)
0.4(+0.015)
0(0)
2.0
(0.078)
• Connect the rated cables only.
• Connect using a driver which is able to apply the rated
torque to the screws.
• If the terminal is loose, fire may occur caused by arc. If
the terminal is connected too firmly, the terminal may
be damaged.
Tightening torque
ɵ˙ଗ˙ϩ Ęଗ
M4 0.87 to 1.30 0.8 to 1.2
M5 1.45 to 2.17 2.0 to 3.0
CAUTION
• When connecting cables, you can connect the cables to
the electrical part or connect them through the holes
below depending on the spot.
•
•
Connect the communication cable between the indoor
and outdoor units through a conduit to protect against
external forces, and feed the conduit through the wall
together with refrigerant piping.
Remove all burrs at the edge of the knock-out hole and
secure the cable to the outdoor knock-out using lining and
bushing with an electrical insulation such as rubber and so on.
• Must keep the cable in a protection tube.
• Keep distances of 1.97 inch(50mm) or more between
power cable and communication cable.
• When the cables are connected through the hole,
remove the Plate bottom.