EasyManua.ls Logo

Samsung AC026HBLDKH - Troubleshooting

Samsung AC026HBLDKH
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
Troubleshooting
Abnormal conditions
Indicators
Remarks
Concealed Type
Green Red
Standard Type
Power reset
X X X X
Error of Room sensor in the indoor
unit(Open/Short)
X X X X
Error of EVA-IN,EVA-OUT sensor in the indoor
unit(Open/Short)
X X X
Error of Fan motor in the indoor unit X
X X X
Error of Outdoor or Terminal Block Thermal
Fuse(Open)
X X
Clogging of outdoor's service valve
X X
Detection of the float switch
X X
X
Error of EEPROM or OPTION SETTING
1. No communication for 2 minutes
between indoor units
(Communication error for more than 2 minutes)
2. Indoor unit receiving the
communication error from outdoor unit
3. Outdoor unit tracking 3 minutes error
4. When sending the communication
error from the outdoor unit, the
mismatching of the communication num-
bers and installed numbers after comple-
tion of tracking.
(Communication error for more than 2 minutes)
X X X
1. Indoor unit error
(Display is unrelated
with operation)
2. Outdoor unit error
(Display is unrelated
with operation)
If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
On
Flickering
X
Off
If an error occurs during the operation, one or more LED flickers and the operation is stopped except the LED.
If you re-operate the air conditioner, it operates normally at first, then detect an error again.
LED Display on the receiver & display unit