COMMISSION DELEGATED REGULATION (EU) No 626/2011
i)
PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS)
ii)
A
Supplier's name - Samsung Electronics Co., Ltd,
B
Model name (Indoor/Outdoor) -
AC120RN4PKG/
AC120RXADKG
AC120RN4PKG/
AC120RXADNG
AC100RNMDKG/
AC100RXADKG
AC100RNMDKG/
AC100RXADNG
AC120RNMDKG/
AC120RXADKG
AC120RNMDKG/
AC120RXADNG
C
Sound Power Level (Indoor/Outdoor) dB(A) 61 / 70 61 / 70 58 / 69 58 / 69 62 / 70 62 / 70
D
Refrigerant name
1)
- R-32 R-32 R-32 R-32 R-32 R-32
E
GWP - 675 675 675 675 675 675
F
SEER - 6,0 6,0 5,9 5,9 5,8 5,8
G
Energy efficiency class (SEER) - A+ A+ A+ A+ A+ A+
H
Q
CE
2)
(cooling season) kWh/a
iii)
700 700 593 593 724 724
I
Pdesignc kW 12,0 12,0 10,0 10,0 12,0 12,0
J
SCOP (Average) - 4,0 4,0 4,0 4,0 4,0 4,0
K
Energy efficiency class SCOP (Average) - A+ A+ A+ A+ A+ A+
L
Q
HE
3)
heating season (Average) kWh/a
iii)
2275 2275 1820 1820 2275 2275
M
Pdesignh (Average) kW 6,5 6,5 5,2 5,2 6,5 6,5
N
Back up heating capacity(Average) kW 0 0 0 0 0 0
O
Declared capacity (Average) kW 6,5 6,5 5,2 5,2 6,5 6,5
P
Other heating seasons suitable for use -
'-iv)
Q
SCOP (Warmer) - - - - - -
R
Energy efficiency class SCOP (Warmer) - -----
S
Q
HE
3)
heating season (Warmer) kWh/a
iii)
-----
T
Pdesignh (Warmer) kW -----
U
Back up heating capacity (Warmer) kW - ----
V
Declared capacity (Warmer) kW - ----
W
SCOP (Colder) - -----
X
Energy efficiency class SCOP (Colder) - - ----
Y
Q
HE
3)
heating season (Colder) kWh/a
iii)
-----
Z
Pdesignh (Colder) kW - - - - -
AA
Back up heating capacity (Colder) kW - - - - -
AB
Declared capacity (Colder) kW -----
1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would
contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to [675]. This means that if 1 kg of this
refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [675] times
higher than 1 kg of CO
2
, over a period of 100 years.
Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always
ask a professional.
2 Energy consumption “XYZ” kWh per year, based on standard test results.
Actual energy consumption will depend on how the appliance is used and where it is located.
3 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend