EasyManua.ls Logo

Samsung AE160MXTPEH User Manual

Samsung AE160MXTPEH
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ECO HEATING SYSTEM CONTENTS
ECO HEATING SYSTEM
OUTDOOR UNIT
HYDRO UNIT
TANK INTEGRATED
HYDRO UNIT
1. Precautions
2. General Overview
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram
6. Wiring Diagram
7. Piping Diagram
8. Reference Sheet
Model :
AE044MXTPEH
AE066MXTPEH
AE090MXTPEH
AE090MXTPGH
AE120MXTPEH
AE120MXTPGH
AE160MXTPEH
AE160MXTPGH
AE090MNYDEH
AE090MNYDGH
AE160MNYDEH
AE160MNYDGH
AE200TNWTEH
AE260TNWTEH
TDM PLUS

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Samsung AE160MXTPEH and is the answer not in the manual?

Samsung AE160MXTPEH Specifications

General IconGeneral
BrandSamsung
ModelAE160MXTPEH
CategoryHeating System
LanguageEnglish

Summary

Precautions

Precautions for the Service

Safety guidelines for service personnel when handling equipment.

Precautions related to static electricity and PL

Warnings about static electricity and potential hazards during repair.

Precautions for the Safety

General safety measures to prevent electric shock, fire, and injury.

Precautions for handling a system containing refrigerants

Safety guidelines for handling refrigerants to prevent harm.

Precautions for the brazing

Safety procedures for brazing refrigerant pipes.

Precautions for charging refrigerants

Safety measures for charging refrigerants.

Disassembly and Reassembly

Hydro Unit

Step-by-step guide for disassembling the Hydro Unit.

Outdoor Unit

Step-by-step guide for disassembling the Outdoor Unit.

Troubleshooting

Communication error after finishing tracking (E202)

Detailed steps for E202 communication errors.

Temperature sensor error (E221, E231, E251, E320)

Troubleshooting temperature sensor errors.

Fan error (E458, E475)

Troubleshooting fan errors.

Compressor error (E461, E467)

Troubleshooting compressor errors.

Current trip error (E462, E463)

Troubleshooting current trip errors.

IPM(IGBT module) over current error (E464)

Troubleshooting IPM over current errors.

DC-link voltage under/over error (E466)

Troubleshooting DC-link voltage errors.

GAS leak error(E554)

Troubleshooting gas leak errors.

Outdoor unit is not powered on – Initial diagnosis

Initial steps for diagnosing power issues in the outdoor unit.

Outdoor unit power supply error

Troubleshooting outdoor unit power supply errors.

Related product manuals