How to troubleshoot [Inverter] OTP error on Samsung Heating System?
- MmstevensSep 15, 2025
If your Samsung Heating System displays an inverter OTP error, check the EEPROM DATA and ensure the PCB is operating normally.
How to troubleshoot [Inverter] OTP error on Samsung Heating System?
If your Samsung Heating System displays an inverter OTP error, check the EEPROM DATA and ensure the PCB is operating normally.
What to do if a gas leak error is detected in Samsung Heating System?
If your Samsung Heating System indicates a gas leak error, you should check the coolant charging status. Also, examine the indoor EVA sensor. Ensure the outdoor unit service valve is open and verify that the indoor/outdoor installation pipe and wiring are correctly installed.
How to fix [Inverter] total current error/ PFC over current error in Samsung Heating System?
If your Samsung Heating System is showing an inverter total current error or PFC over current error, begin by checking the input power. Next, verify the coolant charging status. Finally, ensure that the outdoor fan is operating normally.
How to troubleshoot outdoor fan 1 error on Samsung Heating System?
If your Samsung Heating System is showing an outdoor fan 1 error, you should check the input power connection status. Verify the connection status between the motor and outdoor unit PCB. Also, inspect the indoor/outdoor fuse.
How to fix [Inverter] compressor startup error in Samsung Heating System?
If you're experiencing a compressor startup error on your Samsung Heating System, check the compressor connection status. Also, check the resistance between different phases of the compressor.
How to troubleshoot indoor temperature sensor (open/short error) -Zone2 on Samsung Heating System?
If your Samsung Heating System displays an indoor temperature sensor (open/short error) for Zone2, check the indoor unit room temperature sensor and the indoor unit PCB connector CNS043 Terminal(B15/B16).
What to do if IPM is overheated in Samsung Heating System?
If the IPM is overheated in your Samsung Heating System, check the INVERTER PBA's temperature. Power off and cool down the INVERTER PBA, then restart the outdoor unit.
How to troubleshoot indoor temperature sensor (open/short error) -Zone1 on Samsung Heating System?
If your Samsung Heating System displays an indoor temperature sensor (open/short error) for Zone1, check the indoor unit room temperature sensor and the indoor unit PCB connector CNS043(White).
What to do when Samsung Heating System OUTDOOR UNIT is under protection due to overload?
If the outdoor unit of your Samsung Heating System is under protection due to overload, check the cycle status. Also, check the compressor when it starts.
What to do for indoor unit address setting error in Samsung Heating System?
If you encounter an indoor unit address setting error on your Samsung Heating System, check the address setting of the indoor units.
Brand | Samsung |
---|---|
Model | AE060RXEDEG |
Category | Heating System |
Language | English |
Guidelines for servicing the equipment, ensuring proper procedures and safety.
Warnings about static electricity and product liability during repair.
Essential safety measures to prevent electric shock, fire, and injury during operation.
Safety procedures for handling refrigerants to protect health and the environment.
Safety guidelines for brazing operations, including material handling and gas usage.
Procedures and safety measures for charging refrigerants into the system.
Highlights the key features and technologies of the Eco Heating System.
Detailed technical specifications for outdoor and hydro units.
Lists specifications and details for optional accessories available for the system.
Step-by-step guide for disassembling and reassembling the hydro unit.
Detailed instructions for disassembling and reassembling the outdoor unit.
Troubleshooting guide for error codes displayed on the wired remote controller.
Diagnostic steps based on observed system symptoms and errors.
Troubleshooting specific to the Hydro Unit and its components.
Pre-diagnostic checks and operational modes for system assessment.
Further troubleshooting guidance based on specific error codes and symptoms.
Visual representation of the PCB layout for the Hydro Unit with component identification.
Diagram of the MAIN PCB for the Outdoor Unit with component labels.
Wiring schematics for Tank Integrated Hydro Units.
Wiring diagrams for the Outdoor Unit, covering different phase types.
Guide to understanding model codes and their components.
Schematic and component list for the split tank integrated hydro unit.
Schematic and component list for the mono tank integrated hydro unit.
System diagram and component list for the split Hydro Unit.
Procedure for checking and updating FSV data using S-NET Pro2 software.
Instructions for exporting and importing EHS FSV values using XML files.