E-17
1
Prepare a compressor and the following tools.
Tools Crimping pliers
Connection
sleeve (mm)
Insulation tape
Contraction tube
(mm)
Spec
MH-14 20xØ6.5(HxOD) Width 19mm 70xØ8.0(LxOD)
Shape
2
As shown in the figure, peel off the shields from the rubber or wire of the
power cable.
- Peel off 20 mm of the wire shields of the tube installed already.
3
Insert both sides of core wire of the power cable into the connection
sleeve.
Method 1
Push the core wire into the sleeve
from both sides.
Method 2
Twist the wire cores together and
push it into the sleeve.
Connection sleeve
Connection sleeve
4
Using a compressor, compress the two points and flip it over and compress
another two points in the same location.
- The compression dimension should be 8.0.
- After compressing it, pull both sides of the wire to make sure it is rmly
pressed.
Compression
dimension
Method 1
Compress it 4 times.
5 mm
Method 2
Compress it 4 times.
5 mm
20
120
60
202020
180
Power cable
(Unit: mm)
Wire tube power cable
How to connect your extended power cables
After peeling off the tube wire, you must insert a contraction tube.
For information about the power cable specifications for
indoor and outdoor units, refer to the installation manual.