21
English
Installation Procedure
2 As shown in the figure, peel off the shields from the
rubber and wire of the power cable.
࡛ Peel off 20 mm of cable shields from the pre-
installed tube.
Power cable
(Unit: mm)
20 20 20
60
120
180
Pre-installed tube
for the power cable
202020
60
120
180
CAUTION
࡛ For information about the power cable
specifications for indoor and outdoor units, refer to
the installation manual.
࡛ After peeling off cable wires from the pre-installed
tube, insert a contraction tube.
3 Insert both sides of core wire of the power cable into
the connection sleeve.
࡛ Method 1: Push the core wire into the sleeve from
both sides.
࡛ Method 2: Twist the wire cores together and push it
into the sleeve.
Connection sleeve
Method 1
Connection sleeve
Method 2
CAUTION
࡛ If cable wires are connected without using connecting
sleeves, their contact area becomes reduced, or
corrosion develops on the outer surfaces of the wires
(copper wires) over a long time. This may cause an
increase of resistance (reduction of passing current)
and consequently may result in a fire.
4 Using a crimping tool, compress the two points and
flip it over and compress another two points in the
same location.
࡛ The compression dimension should be 8.0.
࡛ After compressing it, pull both sides of the wire to
make sure it is firmly pressed.
Compress it 4 times.
5 mm
Method 1
Compress it 4 times.
5 mm
Method 2
5 Wrap it with the insulation tape twice or more and
position your contraction tube in the middle of the
insulation tape.
Method 2Method 1
Insulation tape
40 mm
Insulation tape
35 mm
6 Apply heat to the contraction tube to contract it.
Method 2Method 1
Contraction tube Contraction tube
7 After tube contraction work is completed, wrap it with
the insulation tape to finish.
Three or more layers of insulation are required.
Method 2Method 1
Insulation tape Insulation tape