Installation Procedure
Sub indoor unit (BackUp Unit)
1 (Required) Enable the external contact control (with the installation option 02 series SEG14 - Reverse Control).
2 Connect the S-net pro2 to F1 and F2.
3 Enable the entrance control and set the mode, set temperature, and fan speed in the S-net pro2.
࡛ Setting the sub indoor unit in the S-net pro2
a
b
c
a Select Control for Entering Room.
b Select the sub indoor unit.
c Set the operation mode, fan speed, and set
temperature.
࡛ Operation when the external contact settings and the ETO settings overlap
Main indoor unit
Enable of ETO Enable of external contact Error port output
XX Ęࢩ
X O Output due to an error
OX
Output by ETO entrance conditions
࣑ϩʪΧʪθɇϩЇθʪࢩϩʪࢩʪθθͱθͱʀʀЇθθʪʀʪ
OO
Output by ETO entrance conditions
࣑ϩʪΧʪθɇϩЇθʪࢩϩʪࢩʪθθͱθͱʀʀЇθθʪʀʪ
࢜ŵʪɇʒцϩͱʀͱϩθͱϩ˵ʪɇʀͱϩɇʀϩΧЇϩ
Sub indoor unit
Enable of entrance control Enable of external contact Operation when outputting Main
XX Ęࢩ
X O On with the previous operation conditions
O O On with the entrance control enabled