Troubleshooting
4-34 Samsung Electronics
- Big Ceiling
Error detection and reoperation
If error occurs during the operation, badness is indicated by LED flickering and all operation is stopped except LED.
If you re-operate the air conditioner, it operates normally at first, then detect an error again.
Indoor unit LED lamp display at error detecting
Err or mode
Product opera tion with error
Remarks
Blue GreenOrange Red
Power reset
ስΉ Ή Ή
0.5[S]=On, O.5[S]=Off
Operation on
مΉ Ή Ή
Operation off
ΉΉΉΉ
-
Reservation
ΉمΉ Ή
-
Filter sign
ΉΉمΉ
-
Defrosting
ስΉ Ή Ή
1[S]=On, 9[S]=Off
Communication error between indoor
units
ΉስΉ Ή
-
EEPROM error / EEPROM option err or
ስΉ Ήስ
-
Err or of t emperature sensor in indoor
unit(open/short)
ΉΉΉ
-
Err or of outdoor Unit/ Self-Diag n osis
ΉΉΉ
-
Err or of the indoor Unit pipe sensor
ΉስΉስ
Indoor fan err or
ስስ Ή Ή
Thermal Fuse open error
ስΉስΉ
Indoor unit float S/W 2nd detection
ΉስስΉ
: On : Flickering : Off
- If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
- If you re-operate the air conditioner ,it operates nomally at first,then detects an error again.
- If the LED displays olny one color, it is turned on for a second and turned off for a second.
- If the LED displays more than two colors , each color is shown for a second alternately.