EasyManua.ls Logo

Samsung AM054JNHDCH/AA - Constant Rate Compressor Discharge Temperature Sensor Error (OPEN;SHORT)

Samsung AM054JNHDCH/AA
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Samsung Electronics 4-81
4-4-42 Constant Rate Compressor Discharge Temperature Sensor Error (OPEN/SHORT)
(Operation) ×(Reservation) (Blast) ×(Filter) ×(Defrost)
,
(Compr essor 2, Compressor 3)
t$POTUBOUSBUFDPNQSFTTPSEJTDIBSHFUFNQFSBUVSFTFOTPS01&/4)035QSPCMFN
t3FGFSUPUIFJOTQFDUJPONFUIPECFMPX
Indoor Unit Display
Judgment Method
Special Cause
Outdoor Unit Display
1. Inspection Method
Did the connector for
the outdoor constant rate compressor discharge
temperature sensor break away
from the PCB?
Did the resistance value
significantly stray from the following
temperatu
re table?
Separate the connector for the outdoor constant
rate compressor discharge temperature sensor from
the PCB, and measure the resistance value between
the 2 terminals.
Restart operation after chang
ing PCB.
Restart operation after connecting
the connector to PCB
Change this part as it is the fault of
the constant rate compressor discharge
temperature sensor itself.
Yes
No
No
Yes
TemperatureC)
130
120
100
80
60
25
20
10
0
Resistance (K)
8.9
11.2
18.5
32.0
59.0
200.0
242.0
362.0
553.0
Comp. 2 Comp. 3