SYSTEM AIRCONDITIONER
SYSTEM AIRCONDITIONER CONTENTS
1. Precautions
2. Product Specifications
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram and Parts List
6. Wiring Diagram
7. Reference Sheet
AM056/071FN2DEH/TL
AM045/056/071/090/112/128/140FN4DEH/TL
AM045/056/071/090/112/128/140FN4DEH/TS
AM045/056/071/090/112/128/140KN4DEH/TL
AM022/028/036/045/056/060FNNDEH/TL
AM022/028/036/045/056/071FNLDEH/TL
AM056/071/090/112/128/140FNMDEH/TL
AM022/028/036/045/056/071/082JNVDKH/TL
AM140/220/280JNEPEH/EU
AM012/018/024/030/036/048/054/060/072JNZDCH/AA
AM012/018/024/030/036/048/054/060/072TNZDCH/AA
AM160KNMDEH/EU, AM022/045KNJDEH/EU
AM140/280JNPDKH/TK
AM015/022/028/036/045/056/071KNTDEH/
SS
AM015/022/028/036/045/056/071KNQDEH/
SS
AM022/028/036/045/056/071KNQDEH/TL
AM007/009/012/018/020/024KNTDCH/TC
AM007/009/012/018/020/024KNQDCH/TC
AM017/022/028/036KNLDEH/EU
AM045/056/071/090/112/128/140KN4DEH/AR
AM022/028/036KNLDEH/TK
AM022/028/036KNLDEH/TL
AM036/056/071MNFDEH/EU
AM140/220/280MNEPEH/EUAM093MNQDEH/EU
AM093MNQDEH/TK
AE022/028/036/056MNLDEH/EU
AE071/090MNMPEH/EU
AE022/028/036/056/071MNADEH/EU
AE022/028/036/056MNJDEH/EU
AM017/022NN1PEH/EU
AM022/028/036/056/071NN1DEH/
SS
AM022/028/036/045/056/071/082JNADKH/TS
AM022/028/036/045/056/071/082JNVDKH/TS
AM093MNQDEH/TS
AM022/028/036/045/056/060FNNDEH/TS
AM112/128/140FNHDEH/TS
AM180/224JNHFKH/TS
AM036/045/056/071/090/112/128/140HNMPKH/TS
AM112/128/140HNHPKH/TS
AM022/028/036/045/056/071/090/112/128/140KNMDEH/TS
AM160KNMDEH1TS
AM017/022/028/036/045/056/071/090/112/128/140KNLDEH/TS
AM056/071FNCDEH/TS
AM112/140JNCDKH/TS
AM028/036/045HNNDEH/TL
AM140/280RNPDKH/EU
AM015/022/028/036/045/056/071/082TNVDKH/
SS
AM015/022/028/036/045/056/071/082TNADKH/
SS
AM015/022/028/036/045/056/071/082TNQDKH/
SS
AE022/028/036/056/071TNXDEH/EU
AM160/250TNBFEB/EU
AM160/250TNBFGB/EU
AM022/028/036NN1DEH2**
AM022/028/036NN1DKH/**
AM022/028/036/045/056/071/090/112/128/140ANMPKH/EU
AM056/071/090/112/128/140ANHPKH/EU
AM036/045/056/071/090/112/128/140ANMPKH/TS
AM112/128/140ANHPKH/TS
AM012/018/024/030/036/042/048ANHPKH/AZ
AM017/022/028/036/045/056/071/090/112/128/140ANLDKH/EU
AM090/112/128/140MNLDKH/EU
AM005/007/009/012/015/018/024AN1PCH/AA
AM017/022HN1DEH/EU
AM022/028/036FN1DEH/EU
AM071JN1DEH/EU, AM056/071FN2DEH/EU
AM045/056/071/090/112/128/140/FN4DEH/EU
AM045/056/071/090/112/128/140/FN4DEH/AR
AM045/056/071/090/112/128/140KN4DEH/EU
AM022/028/036/045/056/060FNNDEH/EU
AM015HNNDEH/EU
AM112/128/140/220/280FNHDEH/EU
AM036/056/071FNFDEH/EU
AM050/100FNKDEH/EU
AM017/022/028/036/045/056/071/090/112/128/140FNLDEH/EU
AM022/028/036/045/056/071/090/112//128/140FNMDEH/EU
AM056/071FNCDEH/EU
AM028/036/056FNJDEH/EU
AM022/028/036/056/071FNTDEH/EU
AM015HNTDEH/EU
AM022/028/036/045/056/071FNQDEH/EU
AM015HNQDEH/EU
AM160FNBFEB/EU,250FNBFEB/EU
AM160FNBFGB/EU,250FNBFGB/EU
AM160FNBDEH/EU,320FNBDEH/EU,500FNBDEH/EU
AM036/045/056/071/090/112/128/140HNMPKH/EU
AM112/128/140 HNHPKH/EU
AM180/224JNHFKH/EU
AM112/140JNCDKH/EU
AM015/022/028/036/045/056/071/082JNVDKH/EU
AM015/022/028/036/045/056/071/082JNADKH/EU
AM015/022/028/036/045/056/071/082JNVDEH/TK
AM036FN1DEH/TL
AM056/071FN1DEH/TL
INDOOR UNIT

Table of Contents

Other manuals for Samsung AM071NN1DEH/TK

Questions and Answers

  • C
    Carolyn FlynnSep 14, 2025
    What does error E306 mean on a Samsung AM071NN1DEH/TK Air Conditioner?
    • J
      Julia RogersSep 14, 2025
      Error E306 on your Samsung Air Conditioner indicates that the low-pressure sensor is detached.
  • C
    Christopher DavenportAug 25, 2025
    What does error E154 mean on a Samsung Air Conditioner?
    • H
      hjonesAug 25, 2025
      Error E154 on your Samsung Air Conditioner indicates an indoor fan error.
  • M
    Mark WilliamsAug 25, 2025
    What does error E202 mean on my Samsung Air Conditioner?
    • K
      Kenneth AllenAug 26, 2025
      Error E202 on your Samsung Air Conditioner indicates a 3-minute tracking error on the outdoor unit.
  • M
    Mitchell CrossAug 26, 2025
    What does error code E122 mean on a Samsung AM071NN1DEH/TK Air Conditioner?
    • A
      Ashley AdamsAug 26, 2025
      Error code E122 on your Samsung Air Conditioner indicates an error on the Eva-in sensor, which may be shorted or open.
  • Y
    ybradySep 14, 2025
    What does error E428 mean on a Samsung Air Conditioner?
    • A
      April HillSep 15, 2025
      Error E428 on your Samsung Air Conditioner indicates an outdoor unit compression ratio error.
  • L
    Lisa LawrenceSep 23, 2025
    What does error E163 mean on a Samsung AM071NN1DEH/TK?
    • J
      Julie RamosSep 23, 2025
      Error E163 on your Samsung Air Conditioner indicates an EEPROM option error.
  • A
    alicia12Sep 7, 2025
    What does error E241 mean on a Samsung Air Conditioner?
    • N
      Nicole WagnerSep 7, 2025
      Error E241 on your Samsung Air Conditioner indicates that the COND mid sensor is detached.
  • P
    popethomasSep 8, 2025
    What does error E554 mean on a Samsung Air Conditioner?
    • C
      Charles SmithSep 8, 2025
      Error E554 on your Samsung Air Conditioner indicates refrigerant leakage (2nd detection).
  • C
    chernandezSep 23, 2025
    What should I do if my Samsung AM071NN1DEH/TK displays error E108?
    • P
      patricia34Sep 23, 2025
      If your Samsung Air Conditioner displays error E108, change the address and reset the system.
  • T
    Timothy WallaceAug 31, 2025
    What does error E108 mean on a Samsung AM071NN1DEH/TK Air Conditioner?
    • N
      Nicholas BairdAug 31, 2025
      Error E108 on your Samsung Air Conditioner indicates an error due to a repeated communication address.

Summary

Precautions

1-2 Precautions for Static Electricity and PL

Handling PCB power terminals and placement considerations to prevent static electricity damage.

1-3 Precautions for the Safety

Safety guidelines including handling power plugs, wires, and prohibiting multiple outlets to prevent shock or fire.

1-4 Precautions for Handling Refrigerant for Air Conditioner

Environmental and safety cautions for handling refrigerant, including frostbite risks and suffocation hazards.

1-5 Precautions for Welding the Air Conditioner Pipe

Safety measures for welding, including removing flammable objects and purging pipes with nitrogen gas.

Product Specifications

2-1 Product Specifacations

Detailed specifications for various indoor unit types, including power, performance, dimensions, and accessories.

Disassembly and Reassembly

3-1 Indoor Unit

Step-by-step procedures for disassembling and reassembling various indoor unit types, including cassette and duct models.

Troubleshooting

4-1 Check-up Window Description

Description of the check-up window display and its functions, including error codes and indicators.

4-3 Troubleshooting

Comprehensive troubleshooting guide covering various error codes and diagnostic procedures.

4-3-1 Setting Option Setup Method

Instructions for setting indoor unit options and addresses using the remote controller.

4-3-1-1 PCB option code input method

Method for inputting PCB option codes via the remote controller for indoor unit installation settings.

4-3-2 Option Items

Detailed table of available SEG options and their corresponding settings for indoor unit configuration.

4-3-3 What to check before diagnosis

A guide on preliminary checks and common issues to diagnose before proceeding with detailed troubleshooting.

Indoor Unit Sensor Errors

Troubleshooting steps for common indoor unit sensor errors like Open/Short for Room, EVAP IN/OUT sensors.

EEV Errors

Troubleshooting guidance for Electronic Expansion Valve (EEV) opening and closing malfunctions.

Fan Motor Errors

Troubleshooting steps for indoor unit fan motor operational errors, including starting and lock issues.

Communication Errors

Troubleshooting common communication errors between indoor and outdoor units, and MCU units.

MCU Branch Part Setup Errors

Troubleshooting guide for MCU branch part setup errors, including consecutive connections and address overlaps.

Outdoor Unit Sensor Errors

Troubleshooting steps for outdoor unit sensor errors, including temperature and pressure sensor issues.

Compressor Errors

Troubleshooting for compressor-related errors such as down due to high/low pressure or overheat.

PCB Diagram and Parts List

5-1 Indoor Unit

PCB diagrams and parts lists for various indoor unit types, including cassette, duct, and wall-mounted models.

Wiring Diagram

6-1 Indoor

Wiring diagrams for various indoor unit types, including cassette, duct, console, and wall-mounted models.

Samsung AM071NN1DEH/TK Specifications

General IconGeneral
Cooling Capacity7.1 kW
Heating Capacity8.0 kW
Power Supply220-240V, 50Hz
RefrigerantR410A
Air Flow Rate1200 m³/h
Outdoor Unit Dimensions (WxHxD)880 x 638 x 310 mm
TypeSplit System Air Conditioner
Energy Efficiency Ratio (EER)3.21 W/W
Operating Temperature (Cooling)16 ~ 46°C
Operating Temperature (Heating)-15 ~ 24°C
EER10.7

Related product manuals