General safety measures to prevent electric shock and fire hazards during operation and repair.
Step-by-step procedures for disassembling and reassembling the unit.
Troubleshooting guidance for various system symptoms and error codes.
Troubleshooting MCU/Subcooler sensor errors (open/short).
Troubleshooting errors related to the outdoor temperature sensor.
Troubleshooting condenser outlet temperature sensor errors (open/short).
Troubleshooting condenser outlet sensor breakaway errors.
Troubleshooting compressor discharge/top temperature sensor errors.
Troubleshooting compressor discharge/top sensor breakaway errors.
Troubleshooting suction temperature sensor breakaway errors.
Troubleshooting high pressure sensor errors (open/short).
Troubleshooting low pressure sensor errors (open/short).
Troubleshooting suction-2 temperature sensor errors (open/short).
Troubleshooting liquid pipe temperature sensor errors (open/short).
Troubleshooting EVI-in temperature sensor errors (open/short).
Troubleshooting EVI-out temperature sensor errors (open/short).
Troubleshooting suction-2 temperature sensor errors (open/short).
Troubleshooting compressor down due to high pressure protection control.
Troubleshooting compressor down due to low pressure protection control.
Troubleshooting compressor start suspension due to temperature sensor issues.
Troubleshooting errors related to 3-phase input wiring.
Troubleshooting compressor start suspension due to abnormal compression ratio.
Troubleshooting Electronic Expansion Valve (EEV) open errors.
Troubleshooting errors related to refrigerant leakage.
Troubleshooting errors related to CH wire breaking.
Troubleshooting errors related to fan starting.
Troubleshooting errors related to fan lock.
Troubleshooting outdoor fan motor overheating issues.
Troubleshooting fan IPM overheat errors.
Troubleshooting compressor starting errors.
Troubleshooting compressor overcurrent errors.
Troubleshooting overvoltage or low voltage errors.
Troubleshooting DC link voltage sensor errors.
Troubleshooting fan motor overcurrent errors.
Troubleshooting input/output current sensor errors.
Troubleshooting outdoor fan PCB overvoltage/low voltage errors.
Troubleshooting Hall IC errors related to the fan.
Troubleshooting inverter overheat conditions.
Troubleshooting errors from indoor unit and MCU address duplication.