EasyManua.ls Logo

Samsung AM260HXVAGH/EU User Manual

Samsung AM260HXVAGH/EU
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DVM S
AMJXVHGH Series
AMJXVHGR Series
AMHXVAGH Series
AMJXVAGH Series
Air Conditioner
installation manual
imagine the possibilities
Thank you for purchasing this Samsung product.
DVM S HE_IM_DB68-05461A-08_EN.indd 1 2017-03-24 오후 1:38:14
Question and Answer IconNeed help?

Do you have a question about the Samsung AM260HXVAGH/EU and is the answer not in the manual?

Samsung AM260HXVAGH/EU Specifications

General IconGeneral
BrandSamsung
ModelAM260HXVAGH/EU
CategoryAir Conditioner
LanguageEnglish

Summary

Safety precautions

Preparing for installation

Outdoor unit combination

Details compatibility and capacity ranges for combining indoor and outdoor units.

Base construction and installation of the outdoor unit

Refrigerant pipe installation

Refrigerant pipe work

Covers pipe length, height difference, R-410A pressure, and necessary tools.

Pipe installation between the outdoor units

Guides on installing branch joints for connecting outdoor units in modules.

Selecting refrigerant pipe

Guides on selecting pipe sizes based on outdoor unit capacity and length to branch joints.

Allowable length of the refrigerant pipe and the installation examples

Details allowable pipe lengths and installation configurations for H/P systems.

Maximum allowable height difference of pipe

Specifies limits for height differences between outdoor and indoor units.

Maximum allowable pipe length

Details pipe length limits for H/R systems with MCU and Y-joint configurations.

Maximum allowable height difference

Specifies height difference limits for H/R systems, including notes on PDM kits.

Size of the pipe connected to the outdoor unit (A)

Provides tables for selecting pipe sizes based on outdoor unit capacity and length, including size-up options.

Maximum allowable length after branch joint

Defines conditions for pipe length and grade increase for H/R systems.

Size of the pipe between branch joints (B)

Details pipe sizing between branch joints based on indoor unit capacity for different pipe types.

Additional refrigerant

Explains how to calculate and add refrigerant based on outdoor unit capacity and pipe length.

Basic amount of refrigerant within the outdoor unit (kg)

Provides tables for basic refrigerant amounts based on outdoor unit models.

Amount of additional refrigerant depending on the pipe size (ⓐ)

Lists additional refrigerant amounts per meter based on liquid pipe size.

Amount of additional refrigerant for each indoor unit (ⓑ)

Shows additional refrigerant amounts per indoor unit based on capacity and model.

Installing the branch joint between outdoor units

Illustrates installation of joints between outdoor units, noting direction and high-pressure gas pipe applicability.

Method to calculate total amount of additional refrigerant

Explains how to calculate total refrigerant by combining pipe length and indoor unit amounts.

Installing the MCU

Covers MCU specifications and installation of indoor units with MCUs.

Refrigerant pipe welding and safety information

Covers safety precautions and procedures for welding refrigerant pipes.

Pipe installation for an outdoor unit

Connecting refrigerant pipe for outdoor unit

Explains front side and right/left/bottom side connections for pipes.

Caution for welding the pipe to an outdoor unit

Provides cautions for welding pipes to outdoor units, including protection and avoiding damage.

Electrical wiring work

Specification of the circuit breaker and power cable

Lists MCA and MFA values for High EER single and standard module models.

Caution for electrical work

Lists essential electrical work precautions, including ELCB/MCCB installation and cable handling.

Power and communication cable configuration

Illustrates power and communication cable routing for module combinations.

Power wiring diagram

Shows power wiring diagrams for 3-phase 4-wire and single-phase 2-wire supplies.

Connecting the MCU (MCU-S6NEE1N, MCU-S4NEE1N, MCU-S4NEE2N, MCU-S2NEK1N)

Shows an example connection diagram for MCUs with indoor and outdoor units.

Grounding work

Grounding the power cable

Provides a table for grounding power cables based on installation place and humidity.

Air tightness test and vacuum drying

Air tightness test

Explains how to perform an air tightness test using Nitrogen gas.

Vacuum drying pipes and indoor units

Details the process of vacuum drying pipes and indoor units using a vacuum pump.

Charging refrigerant

Setting outdoor unit option switch and key function

Installing and setting the option with tact switch and explanation of the functions

Explains how to set options using tact switches and interpreting the display.

Setting outdoor unit option switch and key function

Lists various optional settings for cooling capacity, heating, current restriction, etc.

Setting the MCU and Pipe Addresses (for HR Only)

Setting the Pipe Addresses Automatically (Auto pipe pairing operation)

Describes the automatic pipe-address setting operation and its requirements.

Things to check after completing the installation

Inspection and test operation

Precautions before test operation

Lists critical precautions before starting test operations, including power supply timing and touching pipes.

Auto trial operation

Explains the auto trial operation process, error handling, and user handover.

Measure to take when E503 error occurs

Provides a flowchart for troubleshooting E503 errors, including checks and corrective actions.

Measure to take when E505, E506 error occurs

Provides a flowchart for troubleshooting E505 and E506 errors, including pressure sensor checks.

Automatic refrigerant amount detection function

Actions to take for the check result

Lists actions for excessive/insufficient refrigerant or supercooling based on detection results.

Related product manuals