Do you have a question about the Samsung AM260KXVAGH/EU and is the answer not in the manual?
Brand | Samsung |
---|---|
Model | AM260KXVAGH/EU |
Category | Air Conditioner |
Language | English |
General safety precautions related to electrical hazards, grounding, and handling of power components.
Provides detailed specifications for various outdoor unit models including capacity, power, and dimensions.
Step-by-step procedures for disassembling and reassembling various outdoor unit models.
Provides a detailed step-by-step guide and cautions for replacing a compressor.
Details on special operations like refrigerant charging, trial operation, and pump down procedures.
Guides for troubleshooting various symptoms through test operations and checks.
Troubleshooting steps for communication errors that occur during system tracking.
Diagnostic procedures for communication errors identified after system tracking.
Steps to resolve communication errors between outdoor unit components or multiple outdoor units.
Troubleshooting for internal communication failures within the outdoor unit's C-Box.
Further steps to diagnose internal PCB communication errors in the outdoor unit's C-Box.
Steps to diagnose and resolve open/short errors for MCU/subcooler entrance/exit sensors.
Procedure for diagnosing and resolving errors related to the outdoor temperature sensor.
Troubleshooting for open/short errors detected in the Cond Out temperature sensor.
Steps to diagnose and resolve breakaway errors for the outdoor Cond Out sensor.
Diagnosing errors related to compressor discharge or top temperature sensors.
Resolving breakaway errors for compressor discharge or top temperature sensors.
Troubleshooting steps for open/short errors detected in the suction temperature sensor.
Diagnosing and resolving open/short errors for the high pressure sensor.
Troubleshooting procedures for open/short errors related to the low pressure sensor.
Steps to diagnose and resolve open/short errors for the suction-2 temperature sensor.
Diagnosing and resolving open/short errors for the liquid pipe temperature sensor.
Troubleshooting procedures for open/short errors related to the EVI In temperature sensor.
Steps to diagnose and resolve open/short errors for the EVI Out temperature sensor.
Diagnosing and resolving open/short errors for the suction-2 temperature sensor.
Troubleshooting steps for compressor shutdown due to high pressure protection.
Resolving compressor shutdown issues caused by low pressure protection control.
Diagnosing suspension of starting issues related to compressor discharge/top temperature sensors.
Troubleshooting steps for errors related to 3-phase input wiring.
Diagnosing suspension of starting issues caused by abnormal compression ratios.
Troubleshooting procedures for EVI EEV open errors.
Steps to diagnose and resolve refrigerant leakage errors.
Troubleshooting steps for CH wire breaking errors.
Diagnosing and resolving errors related to fan starting.
Steps to troubleshoot fan lock errors.
Diagnosing and resolving outdoor fan motor overheating issues.