Do you have a question about the Samsung AM280KXVANH/TL and is the answer not in the manual?
Brand | Samsung |
---|---|
Model | AM280KXVANH/TL |
Category | Air Conditioner |
Language | English |
Troubleshooting flowcharts and procedures for various system symptoms and errors.
Diagnostic steps for troubleshooting when the main PCB shows no power.
Troubleshooting steps for communication errors occurring during tracking between units.
Troubleshooting steps for communication errors that appear after the tracking process.
Procedures for diagnosing communication errors within the outdoor unit or between outdoor units.
Troubleshooting steps for internal communication errors within the Outdoor Unit C-Box.
Further troubleshooting for internal PCB communication errors within the Outdoor Unit C-Box.
Troubleshooting for open/short errors in MCU/Subcooler entrance/exit sensors.
Troubleshooting steps for errors related to the outdoor temperature sensor.
Troubleshooting for open/short errors in the Cond Out temperature sensor.
Troubleshooting for outdoor Cond Out sensor breakaway errors.
Troubleshooting for errors related to compressor discharge or top temperature sensors.
Troubleshooting for breakaway errors in compressor discharge or top temperature sensors.
Troubleshooting for open/short errors in the suction temperature sensor.
Troubleshooting for open/short errors in the high-pressure sensor.
Troubleshooting for open/short errors in the low-pressure sensor.
Troubleshooting for open/short errors in the suction-2 temperature sensor.
Troubleshooting for open/short errors in the liquid pipe temperature sensor.
Troubleshooting for open/short errors in the EVI In temperature sensor.
Troubleshooting for open/short errors in the EVI Out temperature sensor.
Troubleshooting for open/short errors in the suction-2 temperature sensor.
General troubleshooting measures for various other outdoor unit errors.
Troubleshooting for compressor shutdown due to high-pressure protection control.
Troubleshooting for compressor shutdown due to low-pressure protection control.
Troubleshooting for startup suspension caused by compressor discharge or top temperature sensor issues.
Troubleshooting for errors related to 3-phase input wiring issues.
Troubleshooting for startup suspension due to abnormal compression ratio.
Troubleshooting for EVI EEV open errors, including leakage checks.
Troubleshooting steps for refrigerant leakage errors and sensor checks.
Troubleshooting for CH wire breaking errors, including sensor and PCB checks.
Troubleshooting steps for fan starting errors, including motor and PCB checks.
Troubleshooting for fan lock errors, including foreign objects and motor connection checks.
Troubleshooting steps for outdoor fan motor overheating issues.
Troubleshooting for Fan IPM overheat errors, focusing on heat sink and assembly.
Troubleshooting for compressor starting errors, including PCB, valve, and connection checks.
Troubleshooting for compressor overcurrent errors, checking wiring and PCB.
Troubleshooting for overvoltage or low voltage errors related to power input and EMI PCB.
Troubleshooting for DC Link voltage sensor errors, checking connectors and PCBs.
Troubleshooting for fan motor overcurrent errors, checking motor, wiring, and PCB.
Troubleshooting guide for "Undetermined" status related to indoor unit temperature sensors.