AIR CONDITIONER CONTENTS
SYSTEM AIR CONDITIONER
OUTDOOR UNIT
AM080/100/120/140/160/180/200/220/240/2606XV666
AM080/100/120/140/160/180/200/220JXVA66
AM140/160/180/200/220/240/260/280/300KXV666
AM080/100/120/140/160/180/200/220/240/260/280/300MXVA6C
1. Precautions
2. Product Specifications
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram and Parts List
6. Wiring Diagram
7. Cycle Diagram
8. Key Options
9. Test Operation

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Samsung AM240KXVJNH/ID and is the answer not in the manual?

Summary

1. Precautions

1-1 Precautions for the Service

General guidelines for servicing electric parts, harness connections, and physical handling.

1-2 Precautions for the Static Electricity and PL

Handling procedures to prevent static discharge and protect components during PCB repair.

1-3 Precautions for the Safety

Safety measures related to electrical connections, wet hands, wire bending, and grounding.

1-4 Precautions for Handling Refrigerant for Air Conditioner

Safety and environmental guidelines for handling refrigerant release and containers.

1-5 Precautions for Welding the Air Conditioner Pipe

Procedures and safety measures for welding air conditioner pipes, including gas removal and oxide prevention.

1-6 Precautions for Additional Supplement of Air Conditioner Refrigerant

Guidelines for calculating refrigerant amounts and safe injection practices.

2. Product Specifications

2-1-3 Structure of product (Heat Pump: AMSSSSXVSSH Series)

Illustrates the internal structure of heat pump models with component labels.

2-1-4 Structure of product (Heat Recovery: AMSSSSXVSSR Series)

Shows the internal structure of heat recovery models with component identification.

2-1-5 Structure of product (Power supply for 460 V, 60 Hz, 3Φ: AMSSSSXVSSJS Series)

Details the structure of 460V, 60Hz, 3-phase models and their components.

2-1-6 Structure of product (Heat Pump AMSSSKXS Series)

Illustrates the structure of heat pump models in the AMSSSKXS series.

2-1-7 Structure of product (Cooling only AMSSSMXVAFC Series)

Shows the internal structure of cooling-only models in the AMSSSMXVAFC series.

2-1-8 Structure of product (Cooling only AMSSSMXVAGC Series)

Details the structure of cooling-only models in the AMSSSMXVAGC series.

2-2 Product Specifications

Detailed technical specifications for various outdoor unit models.

3. Disassembly and Reassembly

3-2 Disassembly and Reassembly

Step-by-step instructions for disassembling and reassembling various outdoor unit components.

4. Troubleshooting

4-2. Service Operation

Details service operations like refrigerant charging, trial operation, pump down, and vacuuming.

4-3 Appropriate Measures for Different Symptom

Provides troubleshooting steps for various operating symptoms and errors.

5. PCB Diagram and Parts List

5-3 ASSY PCB INVERTER

Diagram and parts list for the inverter PCB assembly.

6. Wiring Diagram

9. Test Operation

9-1 Auto Trial Operation

Overview and procedures for performing the Auto Trial Operation.

9-2 Amount of refrigerant automatically checking

Procedure for automatically checking the refrigerant amount and troubleshooting judged results.

Samsung AM240KXVJNH/ID Specifications

General IconGeneral
ModelAM240KXVJNH/ID
InverterYes
Cooling Capacity24000 BTU/h
Power Consumption (Heating)2200 W
Operating Temperature (Heating)-20 ~ 24 °C