EasyManua.ls Logo

Samsung AM26A1C13 - Removing Excess Humidity

Samsung AM26A1C13
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
3-2-4 When the UP/DOWN Louver Motor Does Not Operate. (Initial Diagnosis)
1) Checklist :
(1) Is input voltage normal?
(2) Is the UP/DOWN louver motor properly connected with the connector (CN61)?
2) Troubleshooting procedure
Remove power cord and plug in again in approx. 5 seconds.
Is operating lamp blinking?
Does operation start when swing button of the remote control unit
pushed?
Voltage at pin #33-#36 of micom (ICO4) change?(Squarewave)
Volatge at pin #10, #11, #12, #13 of IC05 (KID65003)
change?(Squarewave)
UP/DOWN louver motor is faulty.
Driver IC05 (KID65003) is faulty.
Micom (IC04) is faulty.
Normal
Check as in the procedure "No Power parts".
Refer to page 8.
Y
Y
N
N
N
Y
Y
Y
1- 4/17/01 4:41 PM Page 11

Other manuals for Samsung AM26A1C13

Related product manuals