EasyManua.ls Logo

Samsung AQV09F Series User Manual

Samsung AQV09F Series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
E-2
Contents
PREPARING FOR INSTALLATION
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Choosing the Installation Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
INSTALLING THE AIR CONDITIONER
Fixing the Installation Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Purging the Indoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installing and Connecting the Assembly Pipe of the Indoor Unit . . . 10
Cutting or Extending the Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing and Connecting the Drain Hose of the Indoor Unit . . . . . . . 12
Changing Direction of the Drain Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Installing and Connecting the Drain Hose of the Outdoor Unit . . . . . 13
Connecting the Assembly Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
COMPLETING THE INSTALLATION
Purging the Connected Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Performing the Gas Leak Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Fixing the Indoor Unit in Place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Fixing the Outdoor Unit in Place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Final Check and Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Providing Information for User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
08'FORTE_VIVACE_Inv_IM_28492A£¨4£©_E.indd 2 2007-12-6 9:32:16
Question and Answer IconNeed help?

Do you have a question about the Samsung AQV09F Series and is the answer not in the manual?

Samsung AQV09F Series Specifications

General IconGeneral
BrandSamsung
ModelAQV09F Series
CategoryAir Conditioner
LanguageEnglish

Summary

PREPARING FOR INSTALLATION

Safety Precautions

Observe safety precautions before installation, including warnings and cautions for safe operation and potential hazards.

Choosing the Installation Location

Guidance on selecting optimal indoor and outdoor unit locations considering airflow, noise, environment, and installation constraints.

Accessories

Detailed list and illustration of all supplied accessories for indoor/outdoor units, plus optional connection components.

INSTALLING THE AIR CONDITIONER

Fixing the Installation Plate

Steps for correctly mounting the installation plate, including hole drilling, positioning, and securing methods for walls/frames.

Purging the Indoor Unit

Procedure to verify inert gas presence in the indoor unit, checking for leaks before proceeding with installation.

Installing and Connecting the Assembly Pipe of the Indoor Unit

Instructions for connecting refrigerant pipes between units using flare connections, detailing torque specifications and pipe routing.

Cutting or Extending the Pipe

Guidelines for pipe modification, including cutting, flaring, reaming, and tightening techniques for refrigerant pipe connections.

Installing and Connecting the Drain Hose of the Indoor Unit

Steps for proper indoor unit drain hose installation, ensuring correct slope, clearance, and connection to prevent water issues.

Changing Direction of the Drain Hose

Process for detaching and reattaching the indoor unit drain hose and rubber cap to adjust its outlet direction.

Installing and Connecting the Drain Hose of the Outdoor Unit

Procedure to connect the outdoor unit's drain hose to the drain plug for effective condensation drainage during defrost cycles.

Connecting the Assembly Cable

Guide for electrical wiring between indoor and outdoor units, covering cable extension, connection points, and power specifications.

COMPLETING THE INSTALLATION

Purging the Connected Pipes

Steps for removing air from refrigerant pipes via vacuum pump and adding refrigerant, crucial for system performance and longevity.

Performing the Gas Leak Tests

Methods for detecting refrigerant leaks using nitrogen or R410A, including leak detectors and pump-down procedures for safety.

Fixing the Indoor Unit in Place

Instructions for securely mounting the indoor unit onto the installation plate, including pipe insulation and cable management.

Fixing the Outdoor Unit in Place

Guidance for installing the outdoor unit on a stable base or rack, addressing noise, vibration, wind resistance, and proper air discharge.

Final Check and Trial Operation

Procedure to verify all installation connections and conduct a trial run to confirm correct air conditioner operation and functionality.

Providing Information for User

Guidance for installers on instructing end-users about the air conditioner's operation, modes, functions, and basic maintenance.