Samsung AQV12A*A Series - Indoor Temperature Sensor ErrorWhen Is Diplayed

Samsung AQV12A*A Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics 4-7
4-3-2 Indoor Temperature Sensor ErrorWhen is diplayed
1. Checklist :
1) Is the indoor units temperature sensor connected correctly?
2. Troubleshooting procedure
Yes
No
No
Poor ASS’Y PCB Replace
Yes
Poor ASS’Y PCB Replace
Yes
ASS’Y Sensor Replace
SENSOR Resistance Value : 20°C-12.09
30°C-8.31kΩ
35°C-6.94kΩ
40°C-5.83kΩ
No
Is the sensor resistance value
10KΩ ±3% at the room temperature
of 25°C?
Detach the assembly sensor from the
ASS’Y PCB CN43 connector and measure
the sensor resistance with an ohmmeter (tester).
Below 0.5V?
Over 4.9V?
MICOM Error or Connector(CN43) check
Connect the sensor to CN43,
supply power, and measure the voltage of
#1 and #2 of the CN43 connector.