12-2-1Com m unication error
Sam sung Electronics
W hen is diplayed
1. Checklist:
1)Is the com m unication cable betwe en the indoorunitand outdoorunitconnected correctly?
2)Isntthe pow ercable and com m unication cable error?
2. Troubleshooting procedure
12-2
Is the communicaon error
occurred again?
Terminate the service.
NO
Is the connecon of power cable
and communicaon cable normal?
Correct the wrong cable.
NO
YES
Exchange the indoor unit PBA.
Is the communicaon error
occurred again?
Terminate the service.
NO
YES
Exchange the outdoor unit PBA.
YES
Restart aer power o.