Cleaning and MaintenanceCleaning and Maintenance
Problem Solution
An error is indicated.
If the indoor unit indicator blinks, contact the nearest service centre. Be sure to pass
the error code to the service centre.
Noise is generated.
When refrigerant flow changes, noise may be generated, depending on the status of
the air conditioner. This is a normal operation.
Smoke is generated from the
outdoor unit.
If may not be a fire but it can be a steam generated from the outdoor heat exchanger
while the defrost function is running in the Heat mode in winter.
Water drops from the pipe
connections of the outdoor
unit.
Condensation may develop when the ambient temperature changes excessively. This is
a normal operation.
To perform its antimicrobial function this product has been treated with the biocide substance Silver zinc
zeolite.
Information about Refrigerant
Important information: regulation regarding the refrigerant used
This product contains fluorinated greenhouse gases.Do not vent gases into the atmosphere.
CAUTION
If the system contains 5 tCO
2
e or more of fluorinated greenhouse gases, it must be checked for leakage at least
once every 12 months, according to regulation No. 517/2014. This activity must be covered by qualified personnel
only. In the case of the situation above, the installer (or authorized person with responsibility for final check) must
provide a maintenance book, with all the information recorded, according to REGULATION (EU) No. 517/2014 OF THE
EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on fluorinated greenhouse gases.
This indoor unit can be connected to an R-32 or R-410A outdoor unit.
Refrigerant type GWP value
R-32 675
R-410A 2088
• GWP: Global Warming Potential
• Calculating tCO
2
e : kg x GWP/1000