4. Combination Table4. Combination Table
4-2 AJ050TXJ2KG/EU
COOLING
Outdoor unit A B
Cooling
Capacity
Capacity
Power
Consumption
Current
Efc. NOM.
Cooling.
At 35℃/27℃
SEASONAL
EFFICIENCY
(ACCORDING
EN14825)
SEER
Qce
W W W A
A B MIN STD MAX MIN STD MAX MIN STD MAX EER Class kWh
AJ050TXJ2KG 2 Unit
7 7 2000 2000 1300 4000 4700 350 980 1290 1.9 4.5 5.9 4.08 A+++ 8.51 165
7 9 2040 2560 1300 4600 5200 350 1120 1520 1.9 5.1 7 4.11 A+++ 8.51 189
7 12 1820 3180 1400 5000 5500 350 1230 1510 1.9 5.6 6.9 4.07 A+++ 8.51 206
7 18 1430 3570 1400 5000 5500 350 1200 1510 1.9 5.5 6.9 4.15 A+++ 8.51 206
9 9 2500 2500 1400 5000 5500 350 1220 1500 1.9 5.6 6.9 4.1 A+++ 8.54 205
9 12 2080 2920 1400 5000 5500 350 1230 1510 1.9 5.6 6.9 4.07 A+++ 8.51 206
9 18 1670 3330 1400 5000 5500 350 1230 1510 1.9 5.5 6.9 4.15 A+++ 8.51 206
12 12 2500 2500 1400 5000 5500 350 1240 1520 1.9 5.7 7 4.03 A+++ 8.51 206
12 18 2060 2940 1400 5000 5500 350 1240 1520 1.9 5.6 7 4.15 A+++ 8.51 206
HEATING
Outdoor unit A B
Heating
Capacity
Capacity
Power
Consumption
Current
Efc. NOM.
Heating.
At 7℃/20℃
SEASONAL
EFFICIENCY
(ACCORDING
EN14825)
SCOP
P
design
Qhe
W W W A
A B MIN STD MAX MIN STD MAX MIN STD MAX COP Class kW kWh
AJ050TXJ2KG 2 Unit
7 7 2200 2200 1400 4400 4700 280 1010 1210 1.4 4.6 5.5 4.36 A++ 4.61 3.05 927
7 9 2040 3060 1400 5100 5460 280 1310 1610 1.4 6 7. 4 3.89 A++ 4.61 4.21 1277
7 12 2020 3680 1400 5600 6300 280 1290 1710 1.4 5.9 7.8 4.34 A++ 4.61 4.21 1277
7 18 1530 4170 1400 5600 6300 280 1270 1710 1.4 5.7 7.8 4.41 A++ 4.61 4.07 1237
9 9 2850 2850 1400 5600 6300 280 1280 1700 1.4 5.9 7.8 4.38 A++ 4.64 4.21 1270
9 12 2580 3120 1400 5600 6300 280 1290 1710 1.4 5.9 7.8 4.34 A++ 4.61 4.21 1277
9 18 2020 3680 1400 5600 6300 280 1270 1710 1.4 5.7 7.8 4.41 A++ 4.61 4.07 1237
12 12 2850 2850 1400 5600 6300 280 1300 1720 1.4 5.9 7.9 4.31 A++ 4.61 4.21 1277
12 18 2280 3420 1400 5600 6300 280 1280 1720 1.4 5.8 7.9 4.38 A++ 4.61 4.07 1237
NOTE
1
EER and COP declared only for the purpose of tax deductions in force at the time of the creation of this catalog.
2
The above is the value for connecting with the following indoor units.
- Wind Free(PRM) : AR07TXCAAWK, AR09TXCAAWK, AR12TXCAAWK
3
You can not connect a single unit.
4