How to fix [Inverter] current sensor error in Samsung Heating System?
- RRonald BeckerSep 14, 2025
If your Samsung Heating System is showing an inverter current sensor error, check the EEPROM DATA and ensure the PCB is operating normally.
How to fix [Inverter] current sensor error in Samsung Heating System?
If your Samsung Heating System is showing an inverter current sensor error, check the EEPROM DATA and ensure the PCB is operating normally.
What to do if there is a tracking error between remote controller and the Hydro unit in my Samsung Heat Pump?
If your Samsung Heat Pump displays a tracking error between the remote controller and the Hydro unit, the suggested solution is to change parts.
What does a low flow rate error mean on my Samsung AE260RNWMGG Heat Pump, and how do I fix it?
If your Samsung Heat Pump displays a low flow rate error, it indicates that there is not enough water flow. The suggested action is to turn the water pump ON.
What to do if my Samsung AE260RNWMGG shows a short- or open-circuit error for the Zone 1 indoor unit room temperature sensor?
If your Samsung Heat Pump displays a short- or open-circuit error of the room temperature sensor of the Zone 1 indoor unit (detected only when the room thermostat is used), the suggested solution is to change parts.
How to fix [Inverter] DC LINK voltage sensor error in Samsung Heating System?
If your Samsung Heating System displays an inverter DC LINK voltage sensor error, check the input power connection and the status of RY21 and R200 in the INVERTER PCB.
How to troubleshoot thermostat wrong connection error on Samsung Heating System?
If your Samsung Heating System shows a thermostat wrong connection error, check the wiring of the Hydro Unit Thermostat and verify the cooling/heating signal for concurrent wiring issues.
How to troubleshoot compressor V limit error on Samsung Heating System?
If your Samsung Heating System displays a compressor V limit error, check the compressor connection status and the resistance between different phases of the compressor.
What should I check for indoor unit Eva In sensor (Open/Short) error in Samsung Heating System?
If your Samsung Heating System shows an indoor unit Eva In sensor (Open/Short) error, check the indoor unit Eva in sensor location.
How to fix indoor unit communication error on Samsung Heating System?
To address an indoor unit communication error in your Samsung Heating System: * Check the communication cable of the indoor unit. * Check the DC output voltage at the communication terminal.
How to fix [Inverter] compressor startup error in Samsung Heating System?
If you're experiencing a compressor startup error on your Samsung Heating System, check the compressor connection status. Also, check the resistance between different phases of the compressor.
Guidelines for performing service operations safely and correctly.
Safety measures for handling electronic components sensitive to static electricity.
General safety warnings to prevent electrical shock, fire, and injury during operation.
Safety measures for handling refrigerants, including environmental and health concerns.
Detailed technical specifications for outdoor and indoor unit models, including split and mono types.
Step-by-step guide for disassembling the tank integrated hydro unit.
Step-by-step guide for disassembling the outdoor unit.
Diagnosing and resolving issues related to the wired remote controller and error codes.
Guides for identifying and fixing problems based on observed system symptoms.
Troubleshooting flowcharts for communication errors and other system issues.
Guidelines for performing service operations safely and correctly.
Safety measures for handling electronic components sensitive to static electricity.
General safety warnings to prevent electrical shock, fire, and injury during operation.
Safety measures for handling refrigerants, including environmental and health concerns.
Detailed technical specifications for outdoor and indoor unit models, including split and mono types.
Step-by-step guide for disassembling the tank integrated hydro unit.
Step-by-step guide for disassembling the outdoor unit.
Diagnosing and resolving issues related to the wired remote controller and error codes.
Guides for identifying and fixing problems based on observed system symptoms.
Troubleshooting flowcharts for communication errors and other system issues.












Loading...