SAMSUNG EHS
Air Source Heat Pump Installation Guide
AE050JXYDEH/EU
AE090JXYDEH/EU
AE120JXYDEH/EU
AE140JXYDEH/EU
AE160JXYDEH/EU
Date of Issue: 30/01/17
Question and Answer IconNeed help?

Do you have a question about the Samsung AE160JXYDEH/EU and is the answer not in the manual?

Samsung AE160JXYDEH/EU Specifications

General IconGeneral
Heating Seasonal Performance Factor (HSPF)4.0
RefrigerantR410A
TypeHeat Pump
Cooling Capacity16 kW
Heating Capacity18 kW
Operating Temperature Range (Heating)-20 ~ 24°C

Summary

The Outdoor Unit (Boiler) and Control Box

The Control Box (MIM Box) Details

Information on the indoor control box, its components, and dimensions.

Key System Components: Pump and Flow Meter

Circulation Pump Requirements

Details required flow rates and static resistance for the circulation pump.

Flow Switch and Flow Meter Function

Explains the role of flow switch and meter for preventing E911 errors.

System Fluids and Advanced Features

Modulation and Inverters for Efficiency

Explains how inverter units adjust output for efficiency and avoid cycling.

System Flow and Hot Water Cylinder

Achieving Balanced System Flow

Explains achieving balanced flow using hydraulic separators, buffer tanks, or plate heat exchangers.

DHW Cylinder Requirements

Details requirements for DHW cylinders and legionella function.

Fast Connect Installation System

Fast Connect System Overview

Introduces the Fast Connect board for easier installation.

Wiring Fast Connect: Single Heating Zone

Wiring Fast Connect: Multiple Heating Zones

Heating & Hot Water Systems Wiring Diagram

Multi Fuel Wiring Diagram

Multiple Heat Pumps, Heat Only Wiring Diagram

Multiple Heat Pumps, Heat & H/W Wiring Diagram

Combi Hybrid Wiring Diagram

Heating Only Hybrid Wiring Diagram

Wiring and Power Supply Information

Start-Up Procedure and Configuration

Powering Up the System

Guidance on applying power to the indoor and outdoor units.

Field Settings for System Configuration

Electrically Testing System Components

Checking Flow Rate Before Heat Pump Startup

Starting the Unit in Heating Mode

Starting the Unit in Hot Water Mode

Commissioning and Maintenance Sheet

Maintenance of Monobloc Systems

Routine Maintenance Procedure

Step-by-step guide for performing routine maintenance.

Troubleshooting: Problems and Faults

Critical System Faults and Protection

E911 Fault: Insufficient Water Flow

Addresses the E911 fault related to insufficient water flow.