How to fix [Inverter] current sensor error in Samsung Heating System?
- DDave SteinSep 14, 2025
If your Samsung Heating System is showing an inverter current sensor error, check the EEPROM DATA and ensure the PCB is operating normally.
How to fix [Inverter] current sensor error in Samsung Heating System?
If your Samsung Heating System is showing an inverter current sensor error, check the EEPROM DATA and ensure the PCB is operating normally.
What to do if there is a tracking error between remote controller and the Hydro unit in my Samsung Heat Pump?
If your Samsung Heat Pump displays a tracking error between the remote controller and the Hydro unit, the suggested solution is to change parts.
What does a low flow rate error mean on my Samsung AE260RNWSEG, and how do I fix it?
If your Samsung Heat Pump displays a low flow rate error, it indicates that there is not enough water flow. The suggested action is to turn the water pump ON.
What to do if my Samsung AE260RNWSEG shows a short- or open-circuit error for the Zone 1 indoor unit room temperature sensor?
If your Samsung Heat Pump displays a short- or open-circuit error of the room temperature sensor of the Zone 1 indoor unit (detected only when the room thermostat is used), the suggested solution is to change parts.
How to fix [Inverter] DC LINK voltage sensor error in Samsung Heating System?
If your Samsung Heating System displays an inverter DC LINK voltage sensor error, check the input power connection and the status of RY21 and R200 in the INVERTER PCB.
How to troubleshoot thermostat wrong connection error on Samsung Heating System?
If your Samsung Heating System shows a thermostat wrong connection error, check the wiring of the Hydro Unit Thermostat and verify the cooling/heating signal for concurrent wiring issues.
How to troubleshoot compressor V limit error on Samsung Heating System?
If your Samsung Heating System displays a compressor V limit error, check the compressor connection status and the resistance between different phases of the compressor.
What should I check for indoor unit Eva In sensor (Open/Short) error in Samsung Heating System?
If your Samsung Heating System shows an indoor unit Eva In sensor (Open/Short) error, check the indoor unit Eva in sensor location.
How to fix indoor unit communication error on Samsung Heating System?
To address an indoor unit communication error in your Samsung Heating System: * Check the communication cable of the indoor unit. * Check the DC output voltage at the communication terminal.
How to fix [Inverter] compressor startup error in Samsung Heating System?
If you're experiencing a compressor startup error on your Samsung Heating System, check the compressor connection status. Also, check the resistance between different phases of the compressor.
Essential safety measures for servicing the equipment and its components.
Guidelines for handling static electricity and potential hazards during repair.
Critical safety instructions to prevent electric shock, fire, and injury during operation.
Procedures and warnings for safely managing refrigerants, including health risks.
Safety guidelines and procedures to follow when performing brazing operations.
Correct methods and safety measures for charging refrigerant into the system.
Overview of the EHS system's key technological features and benefits.
Detailed technical specifications for outdoor units (Split and Mono) and hydro units.
List and details of optional accessories available for the EHS system.
Step-by-step instructions for disassembling the tank integrated hydro unit.
Procedures for disassembling the outdoor unit, covering various models.
Troubleshooting guide for error codes displayed on the wired remote controller.
Troubleshooting steps for Hydro Unit errors like EEPROM, water pump, sensors, and communication.
Guide to using test run and view modes for system diagnostics and parameter checks.
Troubleshooting for communication errors between indoor, outdoor, and Hydro units.
Diagnosing issues related to sensors, fans, compressors, and power circuits.
Troubleshooting gas leaks and errors in heating/cooling mode operations.
Diagnosing initial power-on issues and outdoor unit power supply errors.
Diagram showing component locations on the Hydro Unit's main PCB.
Diagrams for Outdoor Unit main PCB, Inverter PCB, EMI PCB, and Sub-Heater PCB.
Schematic diagrams illustrating the wiring for Hydro Units (Split/Mono, 1-Phase/3-Phase).
Schematic diagrams showing the wiring for Outdoor Units (Split/Mono, 1-Phase/3-Phase).
Guide to understanding and decoding the model naming convention for EHS units.
Circuit diagrams and part descriptions for Hydro Units (Split/Mono).
Instructions for checking, updating, importing, and exporting FSV data using S-NET Pro2.
Essential safety measures for servicing the equipment and its components.
Guidelines for handling static electricity and potential hazards during repair.
Critical safety instructions to prevent electric shock, fire, and injury during operation.
Procedures and warnings for safely managing refrigerants, including health risks.
Safety guidelines and procedures to follow when performing brazing operations.
Correct methods and safety measures for charging refrigerant into the system.
Overview of the EHS system's key technological features and benefits.
Detailed technical specifications for outdoor units (Split and Mono) and hydro units.
List and details of optional accessories available for the EHS system.
Step-by-step instructions for disassembling the tank integrated hydro unit.
Procedures for disassembling the outdoor unit, covering various models.
Troubleshooting guide for error codes displayed on the wired remote controller.
Troubleshooting steps for Hydro Unit errors like EEPROM, water pump, sensors, and communication.
Guide to using test run and view modes for system diagnostics and parameter checks.
Troubleshooting for communication errors between indoor, outdoor, and Hydro units.
Diagnosing issues related to sensors, fans, compressors, and power circuits.
Troubleshooting gas leaks and errors in heating/cooling mode operations.
Diagnosing initial power-on issues and outdoor unit power supply errors.
Diagram showing component locations on the Hydro Unit's main PCB.
Diagrams for Outdoor Unit main PCB, Inverter PCB, EMI PCB, and Sub-Heater PCB.
Schematic diagrams illustrating the wiring for Hydro Units (Split/Mono, 1-Phase/3-Phase).
Schematic diagrams showing the wiring for Outdoor Units (Split/Mono, 1-Phase/3-Phase).
Guide to understanding and decoding the model naming convention for EHS units.
Circuit diagrams and part descriptions for Hydro Units (Split/Mono).
Instructions for checking, updating, importing, and exporting FSV data using S-NET Pro2.












Loading...