ECO HEATING SYSTEM CONTENTS
ECO HEATING SYSTEM
OUTDOOR UNIT
TANK INTEGRATED
HYDRO UNIT
1. Precautions
2. General Overview
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram
6. Wiring Diagram
7. Reference Sheet
Model :
(Split)
AE040RXEDEG
AE060RXEDEG
AE090RXEDEG
AE090RXEDGG
(Mono)
AE050RXYDEG
AE080RXYDEG
AE120RXYDEG
AE160RXYDEG
AE080RXYDGG
AE120RXYDGG
AE160RXYDGG
(Split)
AE200RNWSEG
AE260RNWSEG
AE260RNWSGG
(Mono)
AE200RNWMEG
AE260RNWMEG
AE260RNWMGG
AE090RNYDEG
AE090RNYDGG
HYDRO UNIT

Other manuals for Samsung AE050RXYDEG

Questions and Answers

  • J
    johnsonjermaineSep 18, 2025
    What to do if Memory(EEPROM) Read Write error occurs on wired remote controller of Samsung Heating System?
    • D
      David JenningsSep 18, 2025
      If you encounter a Memory(EEPROM) Read Write error (Wired remote controller data error) on your Samsung Heating System, check the wired remote controller.
  • M
    Matthew WilliamsAug 25, 2025
    What to do if a gas leak error is detected in Samsung Heating System?
    • J
      jwilliamsAug 25, 2025
      If your Samsung Heating System indicates a gas leak error, you should check the coolant charging status. Also, examine the indoor EVA sensor. Ensure the outdoor unit service valve is open and verify that the indoor/outdoor installation pipe and wiring are correctly installed.
  • J
    jessica05Aug 25, 2025
    How to fix [Inverter] total current error/ PFC over current error in Samsung Heating System?
    • J
      James HernandezAug 26, 2025
      If your Samsung Heating System is showing an inverter total current error or PFC over current error, begin by checking the input power. Next, verify the coolant charging status. Finally, ensure that the outdoor fan is operating normally.
  • M
    mariebarberAug 26, 2025
    How to troubleshoot outdoor fan 1 error on Samsung Heating System?
    • A
      Alexandra Gilbert DVMAug 27, 2025
      If your Samsung Heating System is showing an outdoor fan 1 error, you should check the input power connection status. Verify the connection status between the motor and outdoor unit PCB. Also, inspect the indoor/outdoor fuse.
  • B
    bethany48Sep 19, 2025
    What does Zone 1 water-out temperature sensor error mean on Samsung Heating System?
    • C
      Christopher ReyesSep 22, 2025
      If your Samsung Heating System displays a Zone 1 water-out temperature sensor error, it indicates a short- or open-circuit error of the Zone 1 water-out temperature sensor.
  • T
    thomasmendezSep 23, 2025
    How to troubleshoot thermostat wrong connection error on Samsung Heating System?
    • A
      annehayesSep 23, 2025
      If your Samsung Heating System shows a thermostat wrong connection error, check the wiring of the Hydro Unit Thermostat and verify the cooling/heating signal for concurrent wiring issues.
  • R
    Ronald DavisSep 9, 2025
    What to do if IPM is overheated in Samsung Heating System?
    • J
      Jessica BarronSep 9, 2025
      If the IPM is overheated in your Samsung Heating System, check the INVERTER PBA's temperature. Power off and cool down the INVERTER PBA, then restart the outdoor unit.
  • J
    Joseph WheelerSep 12, 2025
    How to troubleshoot indoor temperature sensor (open/short error) -Zone1 on Samsung Heating System?
    • L
      Laura ParksSep 12, 2025
      If your Samsung Heating System displays an indoor temperature sensor (open/short error) for Zone1, check the indoor unit room temperature sensor and the indoor unit PCB connector CNS043(White).
  • B
    Brendan AndersonSep 3, 2025
    What to do when Samsung Heating System OUTDOOR UNIT is under protection due to overload?
    • N
      Nicholas OliverSep 3, 2025
      If the outdoor unit of your Samsung Heating System is under protection due to overload, check the cycle status. Also, check the compressor when it starts.
  • J
    jacobwebbSep 1, 2025
    What to do for indoor unit address setting error in Samsung Heating System?
    • S
      Stephanie LongSep 1, 2025
      If you encounter an indoor unit address setting error on your Samsung Heating System, check the address setting of the indoor units.

Summary

1. Precautions

1-1 Precautions for the Service

Safety measures for servicing the equipment.

1-2 Precautions related to static electricity and PL

Safety measures against static electricity and PL.

1-3 Precautions for the Safety

General safety guidelines to prevent hazards.

1-4 Precautions for handling a system containing refrigerants

Safety guidelines for handling refrigerants.

1-5 Precautions for the brazing

Safety measures during brazing operations.

1-6 Precautions for charging refrigerants

Safety measures for charging refrigerants.

2. General Overview

2-1 Features of the System

Key features and technologies of the EHS system.

2-1-1 Key features of the EHS(SPLIT)

Specific features of the EHS Split system.

2-2 Product Specifications

2-2-1 Outdoor Unit (Split)

Technical specifications for split outdoor units.

2-2-2 Outdoor Unit (Mono)

Technical specifications for mono outdoor units.

2-3 Specifications of optional items

2-3-1 Accessories

List of accessories available for the unit.

3. Disassembly and Reassembly

3-1 Tank Integrated Hydro Unit; Hydro Unit

Step-by-step guide for disassembling the hydro unit.

3-2 Outdoor Unit

Step-by-step guide for disassembling the outdoor unit.

4. Troubleshooting

4-1 Wired remote controller

Troubleshoot errors related to the wired remote controller.

4-2 Troubleshooting by symptoms

Resolve operational issues based on observed symptoms.

4-3 Tank Integrated Hydro Unit; Hydro Unit

Diagnose and fix errors specific to the hydro unit.

4-4 Items to check before diagnostics

Essential checks before starting troubleshooting procedures.

4-5 Troubleshooting by symptoms

Detailed troubleshooting for various system symptoms.

5. PCB Diagram

5-1 Tank Integrated Hydro Unit; Hydro Unit

PCB layout for the Tank Integrated Hydro Unit.

5-2 Outdoor Unit

PCB layout for the Outdoor Unit.

6. Wiring Diagram

6-1 Tank Integrated Hydro Unit; Hydro Unit

Wiring diagrams for Hydro Units (3 Phase and 1 Phase).

6-2 Outdoor Unit

Wiring diagrams for Outdoor Units (3 Phase and 1 Phase).

7. Reference Sheet

7-1 Index for Model Name

Guide to understanding Samsung EHS model naming conventions.

7-2 Tank intergrated hydro unit(SPLIT)

Component list and diagram for split tank hydro units.

7-3 Tank intergrated hydro unit(MONO)

Component list and diagram for mono tank hydro units.

7-4 Hydro Unit(Split)

Component list and diagram for split hydro units.

7-5 FSV Data check and update using S-NET Pro2

Procedure for checking and updating FSV data using S-NET Pro2.

7-6 EHS FSV Values Import and Export

Instructions for exporting and importing EHS FSV values.

Samsung AE050RXYDEG Specifications

General IconGeneral
BrandSamsung
ModelAE050RXYDEG
CategoryHeat Pump
LanguageEnglish