ECO HEATING SYSTEM CONTENTS
ECO HEATING SYSTEM
OUTDOOR UNIT
TANK INTEGRATED
HYDRO UNIT
1. Precautions
2. General Overview
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram
6. Wiring Diagram
7. Reference Sheet
Model :
(Split)
AE040RXEDEG
AE060RXEDEG
AE090RXEDEG
AE090RXEDGG
(Mono)
AE050RXYDEG
AE080RXYDEG
AE120RXYDEG
AE160RXYDEG
AE080RXYDGG
AE120RXYDGG
AE160RXYDGG
(Split)
AE200RNWSEG
AE260RNWSEG
AE260RNWSGG
(Mono)
AE200RNWMEG
AE260RNWMEG
AE260RNWMGG
AE090RNYDEG
AE090RNYDGG
HYDRO UNIT

Other manuals for Samsung AE040RXED Series

Questions and Answers

  • C
    Corey BrownSep 14, 2025
    How to fix [Inverter] current sensor error in Samsung Heating System?
    • L
      Larry GutierrezSep 14, 2025
      If your Samsung Heating System is showing an inverter current sensor error, check the EEPROM DATA and ensure the PCB is operating normally.
  • S
    Sarah SimmonsAug 25, 2025
    What to do if there is a tracking error between remote controller and the Hydro unit in my Samsung AE040RXED?
    • C
      Cynthia MillerAug 25, 2025
      If your Samsung Heat Pump displays a tracking error between the remote controller and the Hydro unit, the suggested solution is to change parts.
  • M
    Michael WilliamsAug 25, 2025
    What does a low flow rate error mean on my Samsung AE040RXED, and how do I fix it?
    • S
      Shirley WoodsAug 26, 2025
      If your Samsung Heat Pump displays a low flow rate error, it indicates that there is not enough water flow. The suggested action is to turn the water pump ON.
  • R
    Renee ShafferAug 26, 2025
    What to do if my Samsung Heat Pump shows a short- or open-circuit error for the Zone 1 indoor unit room temperature sensor?
    • S
      Sarah MooreAug 26, 2025
      If your Samsung Heat Pump displays a short- or open-circuit error of the room temperature sensor of the Zone 1 indoor unit (detected only when the room thermostat is used), the suggested solution is to change parts.
  • O
    owhiteSep 15, 2025
    How to fix [Inverter] DC LINK voltage sensor error in Samsung Heating System?
    • J
      Jeremiah BakerSep 15, 2025
      If your Samsung Heating System displays an inverter DC LINK voltage sensor error, check the input power connection and the status of RY21 and R200 in the INVERTER PCB.
  • D
    daniellehubbardSep 23, 2025
    How to troubleshoot thermostat wrong connection error on Samsung Heating System?
    • R
      Rachel CarlsonSep 23, 2025
      If your Samsung Heating System shows a thermostat wrong connection error, check the wiring of the Hydro Unit Thermostat and verify the cooling/heating signal for concurrent wiring issues.
  • B
    Brooke WyattSep 7, 2025
    How to troubleshoot compressor V limit error on Samsung Heating System?
    • J
      Jeremy SchroederSep 7, 2025
      If your Samsung Heating System displays a compressor V limit error, check the compressor connection status and the resistance between different phases of the compressor.
  • L
    Leslie CohenSep 8, 2025
    What should I check for indoor unit Eva In sensor (Open/Short) error in Samsung Heating System?
    • A
      angel68Sep 8, 2025
      If your Samsung Heating System shows an indoor unit Eva In sensor (Open/Short) error, check the indoor unit Eva in sensor location.
  • R
    Robert LangSep 2, 2025
    How to fix indoor unit communication error on Samsung Heating System?
    • K
      Kristin ColeSep 2, 2025
      To address an indoor unit communication error in your Samsung Heating System: * Check the communication cable of the indoor unit. * Check the DC output voltage at the communication terminal.
  • N
    nanthonyAug 31, 2025
    How to fix [Inverter] compressor startup error in Samsung Heating System?
    • S
      Stephanie HarrisonAug 31, 2025
      If you're experiencing a compressor startup error on your Samsung Heating System, check the compressor connection status. Also, check the resistance between different phases of the compressor.

Samsung AE040RXED Series Specifications

General IconGeneral
SeriesAE040RXED
CategoryHeat Pump
Cooling Capacity4.0 kW
Energy Efficiency Class (Heating)A++
Energy Efficiency Class (Cooling)A++
RefrigerantR32
Noise Level (Indoor Unit)21 dB(A)
Power Supply220-240V, 50Hz
Operating Temperature Range (Heating)-15°C to 24°C
Operating Temperature Range (Cooling)-10°C to 46°C