SAMSUNG EHS
Air Source Heat Pump Installation Guide
AE050JXYDEH/EU
AE090JXYDEH/EU
AE120JXYDEH/EU
AE140JXYDEH/EU
AE160JXYDEH/EU
Date of Issue: 30/01/17
Question and Answer IconNeed help?

Do you have a question about the Samsung AE090JXYDEH/EU and is the answer not in the manual?

Samsung AE090JXYDEH/EU Specifications

General IconGeneral
TypeHeat Pump
Energy Efficiency Class (Heating)A++
RefrigerantR32
Energy Efficiency Ratio (EER)4.6
Operating Temperature Range Cooling-10°C to 46°C
Operating Temperature Range Heating-15°C to 24°C

Summary

The Outdoor Unit (Boiler)

The Control Box (MIM Box)

Pump

Flow switch and flow meter

Modulation and Inverters

DHW Cylinder

Fast Connect

Wiring Fast Connect With One Heating Zone

Wiring Fast Connect to Multiple Heating Zones

Heating & Hot Water Systems

Heating & Hot Water Systems Wiring Diagram

Multi Fuels

Multi Fuel Wiring Diagram

Multiple Heat Pumps

Multiple Heat Pumps, Heat Only Wiring Diagram

Multiple Heat Pumps, Heat & H/W Wiring Diagram

Combi Hybrids

Combi Hybrid Wiring Diagram

Heating Only Hybrids

Heating Only Hybrid Wiring Diagram

Wiring & Power Supply Information

Start-Up Procedure

Setting up the cylinder immersion heater

Instructions for setting the cylinder immersion heater temperature to 70°C for legionella protection.

Powering Up

Steps for correctly applying power to the indoor and outdoor units for the first time.

Field Settings

If your system is used to heat the house enter these settings into the unit

Configuration settings for heating operation, including weather compensation and flow temperatures.

If your system is heating a hot water cylinder enter these settings into the unit

Configuration settings for domestic hot water heating, including cylinder and legionella settings.

If your system is a hybrid you must also enter these settings

Configuration settings for hybrid systems, covering boiler integration and changeover temperatures.

Cylinder Timer

Electrically testing the unit

Checking flow rate before starting the heat pump

Testing the flow in heating mode

Procedure to test and verify adequate water flow rate in heating mode.

Flow Test: if you don't have a header, heat exchanger or buffer. Setting up the bypass valve

Instructions for setting up a bypass valve to ensure correct flow rates without system separators.

Starting the unit in heating mode

Starting the unit in hot water mode

Commissioning & Maintenance Sheet

Maintenance of Monobloc Systems

Problems and Faults

Heating

Troubleshooting common issues related to heating operation, including thermostat and wiring faults.

Hot water

Troubleshooting common issues related to hot water supply, including cylinder stat and immersion heater faults.

Dead remote controller but red lights are on the indoor PCB

E911 the water is not moving fast enough (my units keep stopping or won't start)

Related product manuals