SAMSUNG EHS
Air Source Heat Pump Installation Guide
AE050JXYDEH/EU
AE090JXYDEH/EU
AE120JXYDEH/EU
AE140JXYDEH/EU
AE160JXYDEH/EU
Date of Issue: 30/01/17
Question and Answer IconNeed help?

Do you have a question about the Samsung AE050JXYDEH/EU and is the answer not in the manual?

Samsung AE050JXYDEH/EU Specifications

General IconGeneral
ModelAE050JXYDEH/EU
CategoryHeat Pump
TypeAir-to-Water
Cooling Capacity5.0 kW
Energy Efficiency Class (Heating)A++
Energy Efficiency Class (Cooling)A+
RefrigerantR32
COP (Heating)4.0
Heating Capacity6.0 kW
Noise Level (Outdoor)50 dB(A)
Power Supply220-240 V
Operating Temperature Range (Heating)-15 - 24 °C
Operating Temperature Range (Cooling)46 °C

Summary

Outdoor Unit and Control Box Details

Fast Connect System

Heating & Hot Water Systems

Heating & Hot Water Systems Wiring Diagram

Diagram illustrating the wiring connections for heating and hot water system configurations.

Multi Fuels System

Multi Fuel Wiring Diagram

Diagram showing the wiring connections for a multi fuels heat pump system.

Multiple Heat Pumps System

Heat Only Wiring Diagram

Wiring diagram for multiple heat pumps configured for heating only applications.

Heat & H/W Wiring Diagram

Wiring diagram for multiple heat pumps configured for both heating and hot water.

Combi Hybrid Systems

Combi Hybrid Wiring Diagram

Diagram illustrating the wiring connections for a combi hybrid heat pump system.

Heating Only Hybrid Systems

Heating Only Hybrid Wiring Diagram

Diagram showing the wiring connections for a heating only hybrid heat pump system.

Wiring & Power Supply Information

Start-Up Procedure

System Flushing and Cylinder Heater Setup

Instructions for flushing the system and setting the cylinder immersion heater temperature.

Powering Up and Initial Checks

Steps for applying power to the units and verifying the controller's initial status.

Field Settings Configuration

Heating System Settings

Configuration options for heating weather compensation, flow temperatures, and run signals.

Hot Water and Hybrid System Settings

Settings for cylinder connection, heating times, legionella cycles, and hybrid boiler integration.

Electrical Testing Procedure

Testing System Components

Steps to electrically test circulation pump, port valves, and heat pump run signals.

Flow Rate Checks and Adjustments

Testing Flow Rate in Heating Mode

Procedure to test and verify the required flow rate for the heat pump in heating mode.

Testing Flow Rate in Hot Water Mode

Procedure to test and verify the required flow rate for the heat pump in hot water mode.

Starting the Unit in Heating Mode

Initiating Heating Mode

Steps to start the heat pump in heating mode, including room stat and pump activation.

Starting the Unit in Hot Water Mode

Initiating Hot Water Mode

Procedure to start the heat pump in hot water mode, setting target temperatures and activating the immersion heater.

Commissioning & Maintenance Sheet

Maintenance of Monobloc Systems

Troubleshooting Common Problems

Controller and PCB Faults

System Faults and Cold Weather Issues

Flow Rate and E911 Fault

Diagnosing E911 faults related to insufficient water flow rate and flow switch function.

Cold Weather Protection and E904 Error

Addresses cold weather startup issues, frost protection, and E904 cylinder stat errors.