EasyManua.ls Logo

Samsung AR09TXEAAWKXEU User Manual

Samsung AR09TXEAAWKXEU
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE
MANUAL
SPLIT-TYPE AIR CONDITIONER
AIR CONDITIONER
CONTENTS
AR07TXCAAWKNEU
AR09TXCAAWKNEU
AR12TXCAAWKNEU
AR07TXEAAWKNEU
AR09TXEAAWKNEU
AR12TXEAAWKNEU
AR18TXEAAWKNEU
AR24TXEAAWKNEU
AR07TXFCAWKNEU
AR09TXFCAWKNEU
AR12TXFCAWKNEU
AR18TXFCAWKNEU
AR24TXFCAWKNEU
-
AR09TXCAAWKXEU
AR12TXCAAWKXEU
-
AR09TXEAAWKXEU
AR12TXEAAWKXEU
AR18TXEAAWKXEU
AR24TXEAAWKXEU
-
AR09TXFCAWKXEU
AR12TXFCAWKXEU
AR18TXFCAWKXEU
AR24TXFCAWKXEU
1. Precautions
2.
3. Alignment and Adjustments
4. Disassembly and Reassembly
5. ASSY CONTROL
6. Wiring Diagram
7. PCB Diagram
8. Operating Instructions
9. Troubleshooting
10. Block Diagram
11. Reference Sheet
AR**T**AAWKN**
AR09TXF**WKX**
AR12TXF**WKX**
AR09TXH**WKX**
AR12TXH**WKX**
AR**T**CAWKN**
AR18TX***WKX**
AR24TX***WKX**
AR09TXC**WKX**
AR12TXC**WKX**
AR09TXE**WKX**
AR12TXE**WKX**
Question and Answer IconNeed help?

Do you have a question about the Samsung AR09TXEAAWKXEU and is the answer not in the manual?

Samsung AR09TXEAAWKXEU Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Energy Efficiency Class (Cooling)A++
Power Supply220-240V, 50Hz
RefrigerantR32
Outdoor Unit Dimensions (W x H x D)720 x 495 x 270 mm
Operating Temperature (Cooling)-10 to 46°C
Operating Temperature (Heating)-15 ~ 24°C

Summary

Precautions

Installing the air conditioner

Guidelines for proper installation of air conditioners, emphasizing professional installation.

Power supply and circuit breaker

Safety instructions regarding power supply, circuit breakers, and electric cords.

During operation

Safety precautions and best practices for operating the air conditioner.

Product specification

Disassembly and Reassembly

Indoor Unit

Step-by-step guide for disassembling and reassembling the indoor unit.

Outdoor Unit (N-V2MD)

Procedure for disassembling and reassembling the outdoor unit (N-V2MD model).

Outdoor Unit (N-WW, SI)

Procedure for disassembling and reassembling the outdoor unit (N-WW, SI models).

Outdoor Unit (Q)

Procedure for disassembling and reassembling the outdoor unit (Q model).

Troubleshooting

Items to be checked first

Initial checks for common air conditioner operational issues.

Communication Error

Diagnoses and resolves communication errors between indoor and outdoor units.

Indoor temperature sensor Error

Troubleshooting steps for indoor room temperature sensor errors.

Indoor fan motor speed detecting error (BLDC fan)

Steps to diagnose and fix indoor fan motor speed detection errors.

Outdoor temperature sensor error

Troubleshooting steps for outdoor temperature sensor errors.

Outdoor Cond temperature sensor error

Troubleshooting steps for outdoor condenser temperature sensor errors.

Outdoor Discharge temperature sensor error

Troubleshooting steps for outdoor discharge temperature sensor errors.

Operation condition secession error

Diagnoses and resolves errors related to operation condition secession.

EEPROM error/OTP error

Troubleshooting steps for EEPROM or OTP errors.

Outdoor Fan motor error

Diagnoses and resolves outdoor fan motor errors.

Compressor starting error

Troubleshooting steps for compressor starting errors.

Compressor wire missing error/rotation error

Diagnoses errors related to compressor wire connection or rotation.

Current sensor error/Input current sensor error

Troubleshooting steps for current sensor and input current errors.

O.C(Over Current) error

Diagnoses and resolves over current (O.C) errors.

Maintenance Procedures