EasyManua.ls Logo

Samsung AR18TSFYBWKXCV - Indoor Temperature Sensor Error

Samsung AR18TSFYBWKXCV
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-3
9-2-2 Indoor temperature sensor Error
Indoor display
7-SEG DISPLAY DESCRIPTION
C121 Indoor room temp sensor error
LED ON
LED BLINKING
LED OFF
1. Checklist :
1) Is the indoor units temperature sensor connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
2. Troubleshooting procedure
YES
YES
NO
NO
YES
Detach the assembled sensor from the PBA
sensor connector and measure the sensor
resistance with ohmmeter(tester)
Assy Sensor Replace
Sensor resistance value : 68°F- 12.09 kohm
86°F - 8.31 kohm
95°F - 6.94 kohm
104°F- 5.83 kohm
Is the sensor resistance value
10kohm±3% at the room temperature
of 77°F ?
Connect the sensor to PBA connector (6pin)
supply power and measure the voltage of #1-#2
in the connector
Below 0.5V or Over 4.5V?
Micom error or connector check
Exchange the indoor PBA
Exchange the indoor PBA