11-1
11-1 Low Refrigerant Pressure Distribution
Note : Please measure the refrigerant pressure after the air conditioner operates on testing
cooling mode during more than 10 minutes.
Indoor Temp. Variation : 68°F ~ 89.6°F
Outdoor Temp. Variation : 23°F ~ 113°F
Indoor Temperature
Outdoor Temperature[
°F
]
Ps [kg/cm
2
g]
89.6°F
84.2°F
80.6°F
75.2°F
69.8°F
11
10
9
8
7
50 68 86 104
11-2 Pressure & Capacity mark
ťͱиʪθࢩ²ʪɇϩ
W cal/s kcal/h Btu/h HP kg.m/s Ib.m/s
1 0.23885 0.85985 3.4121 0.001341 0.10197 0.73756
4.1868 1 3.6 14.286 0.0056146 0.42693 3.088
1.163 0.27778 1 3.9683 0.0015596 0.11859 0.85778
0.29307 0.06999 0.252 1 3.9302x10
-4
0.029885 0.21616
745.7 178.11 641.19 2,544.4 1 76.04 550
9.8067 2.3423 8.4322 33.462 0.013151 1 7.233
1.3558 0.32383 1.0658 4.6262 0.0018182 0.13826 1
11. Reference Sheet