PREPARING THE
INSTALLATION
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
5inch
(125mm)
or more
24inch
(600mm)
minimum
14inch(350mm)
minimum
4inch
(100mm)
minimum
24inch
(600mm)
minimum
4inch(100mm)
minimum
49.3ft(15m) maximum
23ft(7m) maximum
1inch(30mm) or more
5inch (125mm)
or more
Wrap the refrigerant pipes and the drain
hose up in the absorbent pad and the
vinyl tape; refer to page 19.
The indoor unit must be installed at a height of 8.2ft(2.5m) at least from the floor of the room.
The designs of the unit and the connection valve are subject to change according to the model.