12-8Samsung Electronics
12-4 Main Part Inspection Method
Room Temperature Sensor
Room Fan Motor
Outdoor Fan Motor
Stepping Motor
Measure resistance with a tester
Normal At the normal temperature 37k~ 8.3k(-7˚C~+30˚C)
*Refer to Table 12-3-4.
Abnormal , 0
. . .
Open or Short
Measure the resistance between terminals of the connector (CN72) with a tester.
Normal At the normal temperature (10˚C ~ 30˚C)
Abnormal , 0
. . .
Open or Short
Measure the resistance between motor wires with a tester.
Normal At the normal temperature (10˚C ~ 30˚C)
Abnormal , 0
. . .
Open or Short
Measure the resistance between the red wire and each terminal wire with a tester.
Normal About 300 at the normal temperature (20˚C ~ 30˚C)
Abnormal , 0
. . .
Open or Short
Breakdown Inspection MethodPart
Compare terminal Resistance Remark
Yellow, Blue 404.4 ± 10% Main
Yellow, Red 340 ± 10% Sub
Compare terminal Resistance Remark
Yellow, Red 360 ± 10% Main
Black, Yellow 328 ± 10% Sub
24610A(1)_1 11/10/05 6:26 PM Page 10-13