Samsung Electronics 3-9
Installation and Operating Instructions
3. Deicing operation : If temperature of the outdoor pipe thermistor decreases below the specified value during heating opera-
tion, following operation is carried out for safety of the equipment.
Outdoor pipe
Thermistor
temperature (A-Condition) : STANDARD
12[˚C]
-4[˚C]
100min
COUNT
ON
100min
COUNT
OFF
100min
COUNT
ON
100min
5min
Deicing
operation
ON
Deicing
operation
OFF
Deicing
operation
ON
Deicing
operation
OFF
Deicing
operation
ON
Deicing
operation
OFF
Outdoor pipe
Thermistor
temperature (B-Condition) : STANDARD
12[˚C]
-6[˚C]
30min
COUNT
ON
30min
COUNT
OFF
30min
COUNT
ON
30min
5min
Outdoor pipe
Thermistor
temperature (C-Condition) : STANDARD
12[˚C]
-8[˚C]
10min
COUNT
ON
10min
COUNT
OFF
10min
COUNT
ON
2min 5min
100min below
30min below
10min below