Disassembly and Reassembly
Service Manual
3-9
Samsung Electronics
3.4.2 ITB
3.4.3 Fuser unit
1. Remove the top cover. (Refer to 3.4.1)
2. Unplug the connector from OPE PBA.
3. Hold the ITB handle. Pull out the ITB to the
direction of arrow.
1. Remove the right cover.
Unplug 2 connector on the main PBA as shown
below.
Caution - The fuser is very hot. So turn the printer
off and wait until the printer to cool before
replacing it.
2. Remove the 4 screw.
Move the shaft to the right as shown
below. And remove the Fuser unit.