4. Disassembly and Reassembly
4-2 Replacement of High Voltage Transformer
Parts Explaination Photo Explaination
High Voltage
Transformer
3. Remove the mounting bolts.
4. Replace the High Voltage
Transformer
5. After replace, reconnect the
OHDGVFRUUHFWO\DQG¿UPO\
PRECAUTION
Servicemen should remove their watches whenever working close to or replacing the magnetron.
PRECAUTION
There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the
+,*+92/7$*(75$16)250(5VHFRQGDU\DQG¿ODPHQWWHUPLQDOV,WLVH[WUHPHO\GDQJHURXVWRZRUNRQ
or near these circuits with the oven energized.
'2127PHDVXUHWKHYROWDJHLQWKHKLJKYROWDJHFLUFXLWLQFOXGLQJ¿ODPHQWYROWDJHRIPDJQHWURQ