11
3. Disassembly and Reassembly
3-7 Replacement of Fan Motor
Parts Explaination Photo Explaination
Fan Motor
Ventilation Motor
C-Film
Supporter-Fan-Mount
Duct-Fan
1. Remove the outerpanel and back-cover.
2. Discharge the high voltage capacitor.
3. Remove all the lead wires from Magnetron
and High Voltage Capacitor.
4. Remove 2 screws securing the duct fan.
5. Remove 2 screws securing the Supporter-
Fan Mount.
6. Lift the Ventilation Motor Ass’y slightly left
upward and pull it out.
7. Remove lead wires and connectors.
8. Remove a screw securing the C-Film to
the Supporter-Fan-Mount.
9. Turn the fanmotor ass’y over soth at the
bracket side is up.
10. Remove 2 screws securing the Ventilation
Motor.
3-8 Replacement of Tray
Parts Explaination Photo Explaination
Assy
Stirrer
Tray
1. Open the door.
2. Remove the tray by inserting a thin metal tool into the gap
between the oven wall and the tray silicon cover.
3. Insert the new tray by tilting it across the oven cavity.
4. Firstly ¿x the front part (refers to the place where the silicon
cover is thinner than the other 3 edges) and then place the
back ward part carefully and ¿rmly.
NOTE : Be careful when you handle the tray since it is fragle.
3-9 Replacement of Lamp
Parts Explaination Photo Explaination
Assy
Stirrer
Lamp Holder
Lamp Cover
Outer Panel
NOTE : You donn’t need to remove the outer
panel or other parts in order to replace a
lamp
1. Remove a screw securing the lamp cover.
2. Remove the lamp by rotating it clockwise.
3. Replace with a new lamp by rotating it
counter-clockwise
NOTE : If it is necessary to replace the lamp
holder, you can disconnect lead wires by
pushing down on the hole of lead wires using
a long pointed tool.
&0$B;(8LQGE