English-55
INSTALLATION07
R-410Aisamixedtypeofrefrigerant.Itisnecessaryforrechargingunderconditionsofliquid.Whenrechargingrefrigerantfrom
the refrigerant cylinder to the equipment, follow the instructions below.
1. Before recharging, check whether the cylinder has a siphon or not.
There are two ways to recharge the refrigerant.
Charging the refrigerant under conditions of liquid by using a liquid pipe
Cylinder with siphon
Siphon
f
Charge the refrigerant standing the
cylinder upright.
Cylinder without siphon
f
Charge the refrigerant turning the cylinder
upside down.
• IfR-410Arefrigerantischargedwithgas,thecompositionofthechargedrefrigerantchangesandthe
characteristics of the equipment vary.
• Duringthemeasuringoperationofrefrigerantquantityaddeduseelectronicscales.
If cylinder doesnt have syphon, upset it.