Samsung Electronics
Outdoor Error Display and Check Method(cont.)
3-3
Alignment and Adjustments
MAIN
7-Segment
Inverter LED
Content Measures
Product operation status in
case of error
Yellow Green Red
Number of
Times
Outdoor unit
compressor/
outdoor unit
fan
Indoor unit not connected
Check the indoor unit connection
Check the indoor unit number(multi only)
1 Time Operation-off
1min. Time out Comm.
(Display Board : Onboard :
Indoor Outdoor)
Check the indoor unit connection
Check the indoor unit option
1 Time Operation-off
Abnormal Serial
communication(Display
Board:Indoor
Outdoor)
- -
-
- -
Outdoor temp sensor error
(Dual/Single)
Check the connection status of the sensor
Check the sensor location
Check the risistance values of sensor
1 Time Operation-off
Cond temp sensor error
(Dual/Single)
Check the connection status of the sensor
Check the sensor location
Check the risistance values of sensor
1 Time Operation-off
Discharge temp sensor error
(Dual/Single)
Check the connection status of the sensor
Check the sensor location
Check the risistance values of sensor
1 Time Operation-off
Discharge over temperature
(Dual/Single)
- 3 Times Operation-off
Operation condition
secession(HEATING)
Check the operation status of operation mode
Check the temp. sensor
1 Time Operation-off
Operation condition
secession(COOLING)
Fan error
Check the input power connection status
Check the connection status between the motor
and PCB in outdoor unit
Check the fuse of indoor/outdoor units
1 Time Operation-off
Comp Starting error
Check the connection status of the compressor
Check the resistand between different phases in
compressor
5 Times Operation-off
I_Trip error / PFC Over cur
-
rent
Check the input power
Check the refrigerant is filled
Check the outdoor fan operation normally
3 Times Operation-off
IPM Over Current(O.C)
Check the refrigerant is filled
Check the connection status of compressor and
if it operates normally
Check for any obstacles around indoor/outdoor
units
9 Times Operation-off
29347A(1)_1.indd 13 2008-01-23 ソタネト 1:40:12