Samsung Electronics12-1
12-1-1 Tracking process marked on display part
12-1-1
Left numeral is an address that outdoor unit transfers communication.
---
...
- (Calling indoor unit)
12-1-1
Right numeral marks address that is answered.
12-1-1
During the tracking, left calls indoor unit through
---
...
- - - and checks. At this time
connected indoor unit set on " " and the indoor unit set address
marked on right.
Right side mark is marked by when left side is .
(If SW02(MAIN) that set indoor unit address is controlled to " ",
indoor unit number marked on outdoor unit is marked by " ".)
12-1-2 Option set part for Outdoor unit PCB
12. Troubleshooting
12-1 Operation Specification
DISPLAY PART (DS1)
Left Right
Counts of Indoor
Unit Installation
123456789101112131415
123456789ABCDEF
Numbers
of the switch
Example : When the installed indoor unit is one, control the arrow of switch
forward to 0 or 1 as figure.
Setting switch for indoor unit installation numbers
Rotary switchKey
Display